Works about PLETHYSMOGRAPHY
Results: 1955
Discrepancy in finger pulse oximetry reading related to positioning: a case report.
- Published in:
- Proceedings of Singapore Healthcare, 2020, v. 29, n. 2, p. 104, doi. 10.1177/2010105820908284
- By:
- Publication type:
- Article
Bioelectrical Impedance Versus Air-Displacement Plethysmography for Body Fat Measurements in Subjects with Abdominal Obesity: A Comparative Study.
- Published in:
- Applied Sciences (2076-3417), 2025, v. 15, n. 4, p. 2056, doi. 10.3390/app15042056
- By:
- Publication type:
- Article
EFFECTS OF MELATONIN SUPPLEMENTATION ON THE DEVELOPMENT OF HYPERTENSION IN SPONTANEOUSLY HYPERTENSIVE RATS (SHR).
- Published in:
- Malaysian Journal of Medical Sciences, 2008, p. 35
- By:
- Publication type:
- Article
Lungenfunktionsparameter bei experimenteller Stenoseatmung gesunder Probanden im Vergleich zu Patienten mit Atemwegsobstruktion.
- Published in:
- Wiener Klinische Wochenschrift, 2004, v. 116, p. 31
- By:
- Publication type:
- Article
Gynephilic Men's and Androphilic Women's Visual Attention Patterns: The Effects of Gender and Sexual Activity Cues.
- Published in:
- Journal of Sex Research, 2023, v. 60, n. 6, p. 880, doi. 10.1080/00224499.2022.2033675
- By:
- Publication type:
- Article
Using Eye Tracking to Identify Faking Attempts During Penile Plethysmography Assessment.
- Published in:
- Journal of Sex Research, 2014, v. 51, n. 8, p. 946, doi. 10.1080/00224499.2013.832133
- By:
- Publication type:
- Article
Psychophysiologic Assessment of Erectile Response and its Suppression as a Function of Stimulus Media and Previous Experience with Plethysmography.
- Published in:
- Journal of Sex Research, 2000, v. 37, n. 1, p. 53, doi. 10.1080/00224490009552020
- By:
- Publication type:
- Article
Evaluación del interés sexual hacia menores.
- Published in:
- Anuario de Psicología Jurídica, 2016, v. 26, n. 1, p. 30, doi. 10.1016/j.apj.2016.04.007
- By:
- Publication type:
- Article
Peripheral photoplethysmography variability analysis of sepsis patients.
- Published in:
- Medical & Biological Engineering & Computing, 2011, v. 49, n. 3, p. 337, doi. 10.1007/s11517-010-0713-z
- By:
- Publication type:
- Article
Asymmetric time-dependent model for the dynamic finger arterial pressure-volume relationship.
- Published in:
- 2006
- By:
- Publication type:
- journal article
Modelling and simulation of an infant's whole body plethysmograph.
- Published in:
- 2006
- By:
- Publication type:
- journal article
Filtering techniques for the removal of ventilator artefact in oesophageal pulse oximetry.
- Published in:
- 2006
- By:
- Publication type:
- journal article
Pulse wave transit time for monitoring respiration rate.
- Published in:
- 2006
- By:
- Publication type:
- journal article
Non-invasive continuous estimation of blood flow changes in human patellar bone.
- Published in:
- 2006
- By:
- Publication type:
- journal article
A computational system to optimise noise rejection in photoplethysmography signals during motion or poor perfusion states.
- Published in:
- Medical & Biological Engineering & Computing, 2006, v. 44, n. 1/2, p. 140, doi. 10.1007/s11517-005-0008-y
- By:
- Publication type:
- Article
Design and evaluation of a handheld impedance plethysmograph for measuring heart rate variability.
- Published in:
- 2005
- By:
- Publication type:
- journal article
Right-left correlation of the sympathetically induced fluctuations of photoplethysmographic signal in diabetic and non-diabetic subjects.
- Published in:
- 2005
- By:
- Publication type:
- journal article
Non-invasive measurement of systolic blood pressure on the arm utilising photoplethysmography: development of the methodology.
- Published in:
- 2005
- By:
- Publication type:
- journal article
Robust design of finger probe in non-invasive total haemoglobin monitor.
- Published in:
- 2005
- By:
- Publication type:
- journal article
Sympathetically induced spontaneous fluctuations of the photoplethysmographic signal.
- Published in:
- 2004
- By:
- Publication type:
- journal article
Critical review of non-invasive respiratory monitoring in medical care.
- Published in:
- 2003
- By:
- Publication type:
- journal article
Respiratory variations in the reflection mode photoplethysmographic signal. Relationships to peripheral venous pressure.
- Published in:
- 2003
- By:
- Publication type:
- journal article
Neural network for photoplethysmographic respiratory rate monitoring.
- Published in:
- 2003
- By:
- Publication type:
- journal article
Impedance cardiographic measurement of the physiological response to the Valsalva manoeuvre.
- Published in:
- 2003
- By:
- Publication type:
- journal article
Video plethysmography for contactless measurement of respiratory rate in surgical patients.
- Published in:
- Journal of Clinical Monitoring & Computing, 2024, v. 38, n. 1, p. 47, doi. 10.1007/s10877-023-01064-8
- By:
- Publication type:
- Article
Video plethysmography for contactless blood pressure and heart rate measurement in perioperative care.
- Published in:
- Journal of Clinical Monitoring & Computing, 2024, v. 38, n. 1, p. 121, doi. 10.1007/s10877-023-01074-6
- By:
- Publication type:
- Article
Effects of tidal volume challenge on the reliability of plethysmography variability index in hepatobiliary and pancreatic surgeries: a prospective interventional study.
- Published in:
- Journal of Clinical Monitoring & Computing, 2023, v. 37, n. 5, p. 1275, doi. 10.1007/s10877-023-00977-8
- By:
- Publication type:
- Article
A new photoplethysmographic device for continuous assessment of urethral mucosa perfusion: evaluation in a porcine model.
- Published in:
- 2021
- By:
- Publication type:
- journal article
Pulse oximetry based on photoplethysmography imaging with red and green light : Calibratability and challenges.
- Published in:
- 2021
- By:
- Publication type:
- journal article
Continuous hemoglobin and plethysmography variability index monitoring can modify blood transfusion practice and is associated with lower mortality.
- Published in:
- 2020
- By:
- Publication type:
- journal article
Measuring arterial oxygen saturation from an intraosseous photoplethysmographic signal derived from the sternum.
- Published in:
- 2020
- By:
- Publication type:
- journal article
Non-invasive monitoring using photoplethysmography technology.
- Published in:
- 2019
- By:
- Publication type:
- journal article
The importance of sensor contacting force for predicting fluid responsiveness in children using respiratory variations in pulse oximetry plethysmographic waveform.
- Published in:
- 2019
- By:
- Publication type:
- journal article
Video-based heart rate monitoring across a range of skin pigmentations during an acute hypoxic challenge.
- Published in:
- 2018
- By:
- Publication type:
- journal article
Implications of Entropy and Surgical Pleth Index-guided general anaesthesia on clinical outcomes in critically ill polytrauma patients. A prospective observational non-randomized single centre study.
- Published in:
- 2018
- By:
- Publication type:
- journal article
Photoplethysmography for blood volumes and oxygenation changes during intermittent vascular occlusions.
- Published in:
- 2018
- By:
- Publication type:
- journal article
Photoplethysmography respiratory rate monitoring in patients receiving procedural sedation and analgesia for upper gastrointestinal endoscopy.
- Published in:
- 2017
- By:
- Publication type:
- journal article
Comparison of non-invasive peripheral venous saturations with venous blood co-oximetry.
- Published in:
- 2017
- By:
- Publication type:
- journal article
Assessment of an alternative calibration technique to record breathing pattern and its variability with respiratory inductive plethysmography.
- Published in:
- 2017
- By:
- Publication type:
- journal article
Automated, continuous and non-invasive assessment of pulse pressure variations using CNAP<sup>®</sup> system.
- Published in:
- 2017
- By:
- Publication type:
- journal article
A novel multivariate STeady-state index during general ANesthesia (STAN).
- Published in:
- 2017
- By:
- Publication type:
- journal article
Efficacy of bioelectrical impedance analysis during the perioperative period in children.
- Published in:
- 2017
- By:
- Publication type:
- journal article
Journal of Clinical Monitoring and Computing 2016 end of year summary: cardiovascular and hemodynamic monitoring.
- Published in:
- 2017
- By:
- Publication type:
- journal article
Ambient temperature effect on pulse rate variability as an alternative to heart rate variability in young adult.
- Published in:
- 2016
- By:
- Publication type:
- journal article
Investigation of peripheral photoplethysmographic morphology changes induced during a hand-elevation study.
- Published in:
- 2016
- By:
- Publication type:
- journal article
Respiratory variations in the photoplethysmographic waveform amplitude depend on type of pulse oximetry device.
- Published in:
- 2016
- By:
- Publication type:
- journal article
Bioelectrical impedance spectroscopy to estimate fluid balance in critically ill patients.
- Published in:
- 2016
- By:
- Publication type:
- journal article
Detection of intraneural needle-placement with multiple frequency bioimpedance monitoring: a novel method.
- Published in:
- 2016
- By:
- Publication type:
- journal article
Comparison of foot finding methods for deriving instantaneous pulse rates from photoplethysmographic signals.
- Published in:
- 2016
- By:
- Publication type:
- journal article
Photoplethysmography variability as an alternative approach to obtain heart rate variability information in chronic pain patient.
- Published in:
- 2015
- By:
- Publication type:
- journal article