Found: 44
Select item for more details and to access through your institution.
Upper reference limits of transient ischemic dilation ratio for different protocols on new-generation cadmium zinc telluride cameras: A report from REFINE SPECT registry.
- Published in:
- 2020
- By:
- Publication type:
- journal article
Diastolic assessment by CZT-SPECT: Could it be the next best thing for the detection of subclinical chemotherapy-induced cardiotoxicity?
- Published in:
- 2020
- By:
- Publication type:
- Editorial
A further step towards getting cardiac respiratory motion under control.
- Published in:
- 2018
- By:
- Publication type:
- editorial
First validation of myocardial flow reserve assessed by dynamic <sup>99m</sup>Tc-sestamibi CZT-SPECT camera: head to head comparison with <sup>15</sup>O-water PET and fractional flow reserve in patients with suspected coronary artery disease. The WATERDAY study
- Published in:
- European Journal of Nuclear Medicine & Molecular Imaging, 2018, v. 45, n. 7, p. 1079, doi. 10.1007/s00259-018-3958-7
- By:
- Publication type:
- Article
A combined Compton and coded-aperture telescope for medium-energy gamma-ray astrophysics.
- Published in:
- Astronomy & Astrophysics / Astronomie et Astrophysique, 2018, v. 614, p. N.PAG, doi. 10.1051/0004-6361/201731122
- By:
- Publication type:
- Article
Feasibility study of a novel general purpose CZT-based digital SPECT camera: initial clinical results.
- Published in:
- EJNMMI Physics, 2018, v. 5, n. 1, p. 1, doi. 10.1186/s40658-018-0205-z
- By:
- Publication type:
- Article
An Exploratory Study of Washout Rate Analysis for Thallium-201 Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging Using Cadmium Zinc Telluride Detectors.
- Published in:
- Molecular Imaging, 2018, v. 17, p. 1, doi. 10.1177/1536012118782322
- By:
- Publication type:
- Article
Feasibility of data-driven cardiac respiratory motion correction of myocardial perfusion CZT SPECT: A pilot study.
- Published in:
- 2017
- By:
- Publication type:
- journal article
Computer derived transient ischemic dilation ratio for identifying extensive coronary artery disease using a CZT camera and imaging in the upright position.
- Published in:
- 2017
- By:
- Publication type:
- journal article
The Cadmium Zinc Telluride Imager on AstroSat.
- Published in:
- Journal of Astrophysics & Astronomy, 2017, v. 38, n. 2, p. 1, doi. 10.1007/s12036-017-9447-8
- By:
- Publication type:
- Article
Long-Term Stable Surface Treatments on CdTe and CdZnTe Radiation Detectors.
- Published in:
- Journal of Electronic Materials, 2017, v. 46, n. 4, p. 1996, doi. 10.1007/s11664-016-5065-5
- By:
- Publication type:
- Article
Development of new CdZnTe detectors for room-temperature high-flux radiation measurements.
- Published in:
- Journal of Synchrotron Radiation, 2017, v. 24, n. 2, p. 429, doi. 10.1107/S1600577517000194
- By:
- Publication type:
- Article
Comparison of the prognostic value of myocardial perfusion imaging using a CZT-SPECT camera with a conventional anger camera.
- Published in:
- 2017
- By:
- Publication type:
- journal article
Relationships between cardiac innervation/perfusion imbalance and ventricular arrhythmias: impact on invasive electrophysiological parameters and ablation procedures.
- Published in:
- European Journal of Nuclear Medicine & Molecular Imaging, 2016, v. 43, n. 13, p. 2383, doi. 10.1007/s00259-016-3461-y
- By:
- Publication type:
- Article
Prognostic value of the cadmium-zinc-telluride camera: A comparison with a conventional (Anger) camera.
- Published in:
- 2016
- By:
- Publication type:
- journal article
Comparison of biventricular ejection fractions using cadmium-zinc-telluride SPECT and planar equilibrium radionuclide angiography.
- Published in:
- 2016
- By:
- Publication type:
- journal article
Equilibrium gated radionuclide angiocardiography: Its invention, rise, and decline and … comeback?
- Published in:
- 2016
- By:
- Publication type:
- editorial
A study to quantify the effect of patient motion and develop methods to detect and correct for motion during myocardial perfusion imaging on a CZT solid-state dedicated cardiac camera.
- Published in:
- 2016
- By:
- Publication type:
- journal article
Moving ahead with CZT technology.
- Published in:
- 2016
- By:
- Publication type:
- editorial
Erratum to: Moving ahead with CZT technology.
- Published in:
- 2016
- By:
- Publication type:
- journal article
Comparison of the diagnostic accuracies of very low stress-dose with standard-dose myocardial perfusion imaging: Automated quantification of one-day, stress-first SPECT using a CZT camera.
- Published in:
- 2016
- By:
- Publication type:
- journal article
Pre-chemotherapy values for left and right ventricular volumes and ejection fraction by gated tomographic radionuclide angiography using a cadmium-zinc-telluride detector gamma camera.
- Published in:
- 2016
- By:
- Publication type:
- journal article
APPLICATION OF A CZT DETECTOR TO IN SITU ENVIRONMENTAL RADIOACTIVITY MEASUREMENT IN THE FUKUSHIMA AREA.
- Published in:
- Radiation Protection Dosimetry, 2015, v. 167, n. 1-3, p. 348, doi. 10.1093/rpd/ncv277
- By:
- Publication type:
- Article
Effects of Chemomechanical Polishing on CdZnTe X-ray and Gamma-Ray Detectors.
- Published in:
- Journal of Electronic Materials, 2015, v. 44, n. 9, p. 3194, doi. 10.1007/s11664-015-3881-7
- By:
- Publication type:
- Article
Use of Sub-bandgap Illumination to Improve Radiation Detector Resolution of CdZnTe.
- Published in:
- Journal of Electronic Materials, 2015, v. 44, n. 9, p. 3207, doi. 10.1007/s11664-015-3926-y
- By:
- Publication type:
- Article
ROLE OF CARDIAC ULTRAFAST CAMERAS WITH CZT SOLID-STATE DETECTORS AND SOFTWARE DEVELOPMENTS ON RADIATION ABSORBED DOSE REDUCTION TO THE PATIENTS.
- Published in:
- Radiation Protection Dosimetry, 2015, v. 165, n. 1-4, p. 461, doi. 10.1093/rpd/ncv096
- By:
- Publication type:
- Article
CZT camera: moving beyond classical CAD detection?
- Published in:
- 2015
- By:
- Publication type:
- Editorial
Novel Approach to Surface Processing for Improving the Efficiency of CdZnTe Detectors.
- Published in:
- Journal of Electronic Materials, 2014, v. 43, n. 8, p. 2771, doi. 10.1007/s11664-013-2698-5
- By:
- Publication type:
- Article
Structural and Electronic Properties of Gold Contacts on CdZnTe with Different Surface Finishes for Radiation Detector Applications.
- Published in:
- Journal of Electronic Materials, 2014, v. 43, n. 8, p. 2978, doi. 10.1007/s11664-014-3167-5
- By:
- Publication type:
- Article
Importance of correct patient positioning in myocardial perfusion SPECT when using a CZT camera.
- Published in:
- Journal of Nuclear Cardiology, 2014, v. 21, n. 4, p. 695, doi. 10.1007/s12350-014-9897-1
- By:
- Publication type:
- Article
Segmental and global left ventricular function assessment using gated SPECT with a semiconductor Cadmium Zinc Telluride (CZT) camera: Phantom study and clinical validation vs cardiac magnetic resonance.
- Published in:
- Journal of Nuclear Cardiology, 2014, v. 21, n. 4, p. 712, doi. 10.1007/s12350-014-9899-z
- By:
- Publication type:
- Article
Gated tomographic radionuclide angiography using cadmium-zinc-telluride detector gamma camera; comparison to traditional gamma cameras.
- Published in:
- Journal of Nuclear Cardiology, 2014, v. 21, n. 2, p. 384, doi. 10.1007/s12350-013-9844-6
- By:
- Publication type:
- Article
Correlations of Bridgman-Grown CdZnTe Properties with Different Ampoule Rotation Schemes.
- Published in:
- Journal of Electronic Materials, 2013, v. 42, n. 11, p. 3041, doi. 10.1007/s11664-013-2782-x
- By:
- Publication type:
- Article
A Slightly Oxidizing Etchant for Polishing of CdTe and CdZnTe Surfaces.
- Published in:
- Journal of Electronic Materials, 2013, v. 42, n. 11, p. 3059, doi. 10.1007/s11664-013-2625-9
- By:
- Publication type:
- Article
Assessing CZT detector performance for environmental radioactivity investigations.
- Published in:
- Radiation Protection Dosimetry, 2013, v. 154, n. 4, p. 477, doi. 10.1093/rpd/ncs253
- By:
- Publication type:
- Article
Comparison between stress myocardial perfusion SPECT recorded with cadmium-zinc-telluride and Anger cameras in various study protocols.
- Published in:
- European Journal of Nuclear Medicine & Molecular Imaging, 2013, v. 40, n. 3, p. 331, doi. 10.1007/s00259-012-2292-8
- By:
- Publication type:
- Article
Progress in the Development of CdZnTe Unipolar Detectors for Different Anode Geometries and Data Corrections.
- Published in:
- Sensors (14248220), 2013, v. 13, n. 2, p. 2447, doi. 10.3390/s130202447
- By:
- Publication type:
- Article
Comparison between HPGe and CdZnTe detector for the correlation between calculated radioactivity and measured dose using an activated concrete sample.
- Published in:
- Journal of Radioanalytical & Nuclear Chemistry, 2012, v. 294, n. 3, p. 461, doi. 10.1007/s10967-011-1475-2
- By:
- Publication type:
- Article
Slow-Polishing Iodine-Based Etchant for CdTe and CdZnTe Single Crystals.
- Published in:
- Journal of Electronic Materials, 2012, v. 41, n. 10, p. 2838, doi. 10.1007/s11664-012-2001-1
- By:
- Publication type:
- Article
Response of the Internal Electric Field in CdZnTe to Illumination at Multiple Optical Powers.
- Published in:
- Journal of Electronic Materials, 2012, v. 41, n. 10, p. 2874, doi. 10.1007/s11664-012-1922-z
- By:
- Publication type:
- Article
Investigation of Structural Defects in CdZnTe Detector-Grade Crystals.
- Published in:
- Journal of Electronic Materials, 2012, v. 41, n. 10, p. 2908, doi. 10.1007/s11664-012-2007-8
- By:
- Publication type:
- Article
Post-growth Annealing of Cadmium Zinc Telluride Crystals for Room-Temperature Radiation Detectors.
- Published in:
- Journal of Electronic Materials, 2012, v. 41, n. 10, p. 2912, doi. 10.1007/s11664-012-2013-x
- By:
- Publication type:
- Article
Impact of a new ultrafast CZT SPECT camera for myocardial perfusion imaging: fewer equivocal results and lower radiation dose.
- Published in:
- European Journal of Nuclear Medicine & Molecular Imaging, 2012, v. 39, n. 6, p. 1048, doi. 10.1007/s00259-012-2086-z
- By:
- Publication type:
- Article
A selection of recent original research papers.
- Published in:
- 2011
- By:
- Publication type:
- Editorial