Found: 29
Select item for more details and to access through your institution.
Improved intercostal HIFU ablation using a phased array transducer based on Fermat's spiral and Voronoi tessellation: A numerical evaluation.
- Published in:
- Medical Physics, 2017, v. 44, n. 3, p. 1071, doi. 10.1002/mp.12082
- By:
- Publication type:
- Article
Investigation of the influence of B<sub>0</sub> drift on the performance of the PLANET method and an algorithm for drift correction.
- Published in:
- Magnetic Resonance in Medicine, 2019, v. 82, n. 5, p. 1725, doi. 10.1002/mrm.27860
- By:
- Publication type:
- Article
MRI Methods for the Evaluation of High Intensity Focused Ultrasound Tumor Treatment: Current Status and Future Needs.
- Published in:
- Magnetic Resonance in Medicine, 2016, v. 75, n. 1, p. 302, doi. 10.1002/mrm.25758
- By:
- Publication type:
- Article
Ultrasound-Mediated Drug Delivery With a Clinical Ultrasound System: In Vitro Evaluation.
- Published in:
- Frontiers in Pharmacology, 2021, v. 12, p. 1, doi. 10.3389/fphar.2021.768436
- By:
- Publication type:
- Article
Short and long time MR signal behavior of randomly distributed water and fat-numerical simulations.
- Published in:
- NMR in Biomedicine, 2016, v. 29, n. 11, p. 1634, doi. 10.1002/nbm.3615
- By:
- Publication type:
- Article
Real-time volumetric MRI thermometry of focused ultrasound ablation in vivo: a feasibility study in pig liver and kidney.
- Published in:
- NMR in Biomedicine, 2011, v. 24, n. 2, p. 145, doi. 10.1002/nbm.1563
- By:
- Publication type:
- Article
The role of ultrasound and magnetic resonance in local drug delivery.
- Published in:
- Journal of Magnetic Resonance Imaging, 2008, v. 27, n. 2, p. 400, doi. 10.1002/jmri.21272
- By:
- Publication type:
- Article
Local delivery of magnetic resonance (MR) contrast agent in kidney using thermosensitive liposomes and MR imaging-guided local hyperthermia: A feasibility study in vivo.
- Published in:
- Journal of Magnetic Resonance Imaging, 2005, v. 22, n. 4, p. 534, doi. 10.1002/jmri.20416
- By:
- Publication type:
- Article
Stability of real-time MR temperature mapping in healthy and diseased human liver.
- Published in:
- Journal of Magnetic Resonance Imaging, 2004, v. 19, n. 4, p. 438, doi. 10.1002/jmri.20019
- By:
- Publication type:
- Article
Diffusion tensor MRI of the human kidney.
- Published in:
- 2001
- By:
- Publication type:
- journal article
Local hyperthermia with MR-guided focused ultrasound: spiral trajectory of the focal point optimized for temperature uniformity in the target region.
- Published in:
- 2000
- By:
- Publication type:
- journal article
Magnetic resonance temperature imaging for guidance of thermotherapy.
- Published in:
- 2000
- By:
- Publication type:
- journal article
Tumor Drug Distribution after Local Drug Delivery by Hyperthermia, In Vivo.
- Published in:
- Cancers, 2019, v. 11, n. 10, p. 1512, doi. 10.3390/cancers11101512
- By:
- Publication type:
- Article
Reproducibility of human 3D fMRI brain maps acquired during a motor task.
- Published in:
- Human Brain Mapping, 1996, v. 4, n. 2, p. 113, doi. 10.1002/(SICI)1097-0193(1996)4:2<113::AID-HBM3>3.0.CO;2-6
- By:
- Publication type:
- Article
Spectrally selective pencil-beam navigator for motion compensation of MR-guided high-intensity focused ultrasound therapy of abdominal organs.
- Published in:
- Magnetic Resonance in Medicine, 2011, v. 66, n. 1, p. 102, doi. 10.1002/mrm.22784
- By:
- Publication type:
- Article
Three-dimensional spatial and temporal temperature control with MR thermometry-guided focused ultrasound (MRgHIFU).
- Published in:
- Magnetic Resonance in Medicine, 2009, v. 61, n. 3, p. 603, doi. 10.1002/mrm.21887
- By:
- Publication type:
- Article
Real-time adaptive methods for treatment of mobile organs by MRI-controlled high-intensity focused ultrasound.
- Published in:
- Magnetic Resonance in Medicine, 2007, v. 57, n. 2, p. 319, doi. 10.1002/mrm.21124
- By:
- Publication type:
- Article
Automatic spatial and temporal temperature control for MR-guided focused ultrasound using fast 3D MR thermometry and multispiral trajectory of the focal point.
- Published in:
- Magnetic Resonance in Medicine, 2004, v. 52, n. 5, p. 1005, doi. 10.1002/mrm.20280
- By:
- Publication type:
- Article
A PRESTO-SENSE sequence with alternating partial-Fourier encoding for rapid susceptibility-weighted 3D MRI time series.
- Published in:
- Magnetic Resonance in Medicine, 2003, v. 50, n. 4, p. 830
- By:
- Publication type:
- Article
Real-time MR temperature mapping of rabbit liver in vivo during thermal ablation.
- Published in:
- Magnetic Resonance in Medicine, 2003, v. 50, n. 2, p. 322
- By:
- Publication type:
- Article
Feasibility of MR-guided focused ultrasound with real-time temperature mapping and continuous sonication for ablation of VX2 carcinoma in rabbit thigh.
- Published in:
- Magnetic Resonance in Medicine, 2003, v. 49, n. 1, p. 89, doi. 10.1002/mrm.10328
- By:
- Publication type:
- Article
Automatic control of hyperthermic therapy based on real-time Fourier analysis of MR temperature maps.
- Published in:
- Magnetic Resonance in Medicine, 2002, v. 47, n. 6, p. 1065, doi. 10.1002/mrm.10176
- By:
- Publication type:
- Article
Imaging the changes in renal T<sub>1</sub> induced by the inhalation of pure oxygen: A feasibility study.
- Published in:
- Magnetic Resonance in Medicine, 2002, v. 47, n. 4, p. 728, doi. 10.1002/mrm.10127
- By:
- Publication type:
- Article
On-line correction and visualization of motion during MRI-controlled hyperthermia.
- Published in:
- Magnetic Resonance in Medicine, 2001, v. 45, n. 1, p. 128, doi. 10.1002/1522-2594(200101)45:1<128::AID-MRM1017>3.0.CO;2-M
- By:
- Publication type:
- Article
Diffusion tensor MRI of the spinal cord.
- Published in:
- Magnetic Resonance in Medicine, 2000, v. 44, n. 6, p. 884, doi. 10.1002/1522-2594(200012)44:6<884::AID-MRM9>3.0.CO;2-Q
- By:
- Publication type:
- Article
Hyperthermia by MR-guided focused ultrasound: Accurate temperature control based on fast MRI and a physical model of local energy deposition and heat conduction.
- Published in:
- Magnetic Resonance in Medicine, 2000, v. 43, n. 3, p. 342, doi. 10.1002/(SICI)1522-2594(200003)43:3<342::AID-MRM4>3.0.CO;2-6
- By:
- Publication type:
- Article
Fast lipid-suppressed MR temperature mapping with echo-shifted gradient-echo imaging and spectral-spatial excitation.
- Published in:
- Magnetic Resonance in Medicine, 1999, v. 42, n. 1, p. 53, doi. 10.1002/(SICI)1522-2594(199907)42:1<53::AID-MRM9>3.0.CO;2-S
- By:
- Publication type:
- Article
An echo-shifted gradient-echo MRI method for efficient diffusion weighting.
- Published in:
- Magnetic Resonance in Medicine, 1999, v. 41, n. 5, p. 1000, doi. 10.1002/(SICI)1522-2594(199905)41:5<1000::AID-MRM20>3.0.CO;2-G
- By:
- Publication type:
- Article
Susceptibility Insensitive Single Shot MRI Combining BURST and Multiple Spin Echoes.
- Published in:
- Magnetic Resonance in Medicine, 1995, v. 33, n. 3, p. 439, doi. 10.1002/mrm.1910330320
- By:
- Publication type:
- Article