Found: 15
Select item for more details and to access through your institution.
Dosimetric characterization of optically stimulated luminescence dosimeter with therapeutic photon beams for use in clinical radiotherapy measurements.
- Published in:
- 2017
- By:
- Publication type:
- journal article
Total marrow lymphoid irradiation and cyclophosphamide is associated with low toxicity and good outcomes in patients undergoing hematopoietic stem cell transplantation for acute lymphoblastic leukemia and chronic myeloid leukemia in lymphoid blast crises – A phase I study
- Published in:
- Clinical Transplantation, 2023, v. 37, n. 9, p. 1, doi. 10.1111/ctr.15010
- By:
- Publication type:
- Article
Effect of Detector Orientation and Influence of Jaw Position in the Determination of Small-field Output Factor with Various Detectors for High-energy Photon Beams.
- Published in:
- Journal of Medical Physics, 2024, v. 49, n. 1, p. 73, doi. 10.4103/jmp.jmp_148_23
- By:
- Publication type:
- Article
Influence of Jaw Setting in the Determination of Stereotactic Small-Field Output Factors with Different Detectors.
- Published in:
- Journal of Medical Physics, 2022, v. 47, n. 1, p. 65, doi. 10.4103/jmp.jmp_111_21
- By:
- Publication type:
- Article
Response of Nanodot Optically Stimulated Luminescence Dosimeters to Therapeutic Electron Beams.
- Published in:
- Journal of Medical Physics, 2017, v. 42, n. 1, p. 42, doi. 10.4103/0971-6203.202424
- By:
- Publication type:
- Article
Dosimetric evaluation of newly developed well-type ionization chamber for use in the calibration of brachytherapy sources.
- Published in:
- Journal of Medical Physics, 2016, v. 41, n. 4, p. 234, doi. 10.4103/0971-6203.195187
- By:
- Publication type:
- Article
Analysis of small field percent depth dose and profiles: Comparison of measurements with various detectors and effects of detector orientation with different jaw settings.
- Published in:
- Journal of Medical Physics, 2016, v. 41, n. 1, p. 12, doi. 10.4103/0971-6203.177284
- By:
- Publication type:
- Article
Hypofractionated radiation therapy comparing a standard radiotherapy schedule (over 3 weeks) with a novel 1-week schedule in adjuvant breast cancer: an open-label randomized controlled study (HYPORT-Adjuvant)-study protocol for a multicentre, randomized phase III trial.
- Published in:
- 2020
- By:
- Publication type:
- journal article
In-vivo dose measurements with MOSFET dosimeters during MV portal imaging.
- Published in:
- Reports of Practical Oncology & Radiotherapy, 2021, v. 26, n. 1, p. 93, doi. 10.5603/RPOR.a2021.0016
- By:
- Publication type:
- Article
Hypofractionated stereotactic radiotherapy in Spetzler Martin grades 4 and 5 arteriovenous malformations in the pediatric population: Is it a viable alternative?
- Published in:
- Child's Nervous System, 2024, v. 40, n. 4, p. 1185, doi. 10.1007/s00381-023-06244-0
- By:
- Publication type:
- Article
Impact of CT based planning and bladder volume changes on the dosimetry of vaginal vault brachytherapy – CORRIGENDUM.
- Published in:
- 2022
- By:
- Publication type:
- Correction Notice
Impact of CT-based planning and bladder volume changes on the dosimetry of vaginal vault brachytherapy.
- Published in:
- Journal of Radiotherapy in Practice, 2022, v. 21, n. 3, p. 321, doi. 10.1017/S1460396920001235
- By:
- Publication type:
- Article
Output factor measurements with multiple detectors in CyberKnife<sup>®</sup> Robotic Radiosurgery System.
- Published in:
- 2021
- By:
- Publication type:
- journal article
Evaluation of optically stimulated luminescence dosimeter for exit dose dosimetry in radiation therapy.
- Published in:
- 2018
- By:
- Publication type:
- journal article
Feasibility study of total marrow lymphoid irradiation with volumetric modulated arc therapy: clinical implementation in a tertiary care center.
- Published in:
- Strahlentherapie und Onkologie, 2023, v. 199, n. 10, p. 922, doi. 10.1007/s00066-023-02100-x
- By:
- Publication type:
- Article