Found: 33
Select item for more details and to access through your institution.
Simultaneous Acquisition of Diffusion Tensor and Dynamic Diffusion MRI.
- Published in:
- Journal of Magnetic Resonance Imaging, 2023, v. 57, n. 4, p. 1079, doi. 10.1002/jmri.28407
- By:
- Publication type:
- Article
Nonalcoholic Fatty Liver Disease in Patients with Inherited and Sporadic Motor Neuron Degeneration.
- Published in:
- Genes, 2022, v. 13, n. 6, p. 936, doi. 10.3390/genes13060936
- By:
- Publication type:
- Article
Highly Efficient and Accurate Deep Learning–Based Classification of MRI Contrast on a CPU and GPU.
- Published in:
- Journal of Digital Imaging, 2022, v. 35, n. 3, p. 482, doi. 10.1007/s10278-022-00583-1
- By:
- Publication type:
- Article
Nonhuman primates exposed to Zika virus in utero are not protected against reinfection at 1 year postpartum.
- Published in:
- Science Translational Medicine, 2020, v. 12, n. 567, p. 1, doi. 10.1126/scitranslmed.aaz4997
- By:
- Publication type:
- Article
Determining the optimal postlabeling delay for arterial spin labeling using subject-specific estimates of blood velocity in the carotid artery.
- Published in:
- 2019
- By:
- Publication type:
- journal article
Correlation between right ventricular T<sub>1</sub> mapping and right ventricular dysfunction in non-ischemic cardiomyopathy.
- Published in:
- 2018
- By:
- Publication type:
- journal article
Myocardial T1 mapping and determination of partition coefficients at 3 tesla: comparison between gadobenate dimeglumine and gadofosveset trisodium.
- Published in:
- Radiologia Brasileira, 2018, v. 51, n. 1, p. 13, doi. 10.1590/0100-3984.2016.0071
- By:
- Publication type:
- Article
Long T2 suppression in native lung 3-D imaging using k-space reordered inversion recovery dual-echo ultrashort echo time MRI.
- Published in:
- MAGMA: Magnetic Resonance Materials in Physics, Biology & Medicine, 2017, v. 30, n. 4, p. 387, doi. 10.1007/s10334-017-0613-4
- By:
- Publication type:
- Article
Three-dimensional T1 and T2* mapping of human lung parenchyma using interleaved saturation recovery with dual echo ultrashort echo time imaging (ITSR-DUTE).
- Published in:
- 2017
- By:
- Publication type:
- journal article
Submillimeter diffusion tensor imaging and late gadolinium enhancement cardiovascular magnetic resonance of chronic myocardial infarction.
- Published in:
- Journal of Cardiovascular Magnetic Resonance (BioMed Central), 2017, v. 19, p. 1, doi. 10.1186/s12968-016-0317-3
- By:
- Publication type:
- Article
Evaluation of optimized breath-hold and free-breathing 3D ultrashort echo time contrast agent-free MRI of the human lung.
- Published in:
- 2016
- By:
- Publication type:
- journal article
Dose correction for post-contrast T1 mapping of the heart: the MESA study.
- Published in:
- 2016
- By:
- Publication type:
- journal article
Part 1 - Coronary angiography with gadofosveset trisodium: a prospective feasibility study evaluating injection techniques for steady-state imaging.
- Published in:
- 2015
- By:
- Publication type:
- journal article
Reduced scan time three-dimensional FLAIR using modulated inversion and repetition time.
- Published in:
- Journal of Magnetic Resonance Imaging, 2015, v. 41, n. 5, p. 1440, doi. 10.1002/jmri.24679
- By:
- Publication type:
- Article
Optimized three-dimensional sodium imaging of the human heart on a clinical 3T scanner.
- Published in:
- Magnetic Resonance in Medicine, 2015, v. 73, n. 2, p. 623, doi. 10.1002/mrm.25175
- By:
- Publication type:
- Article
Progression of diffuse myocardial fibrosis assessed by cardiac magnetic resonance T mapping.
- Published in:
- International Journal of Cardiovascular Imaging, 2014, v. 30, n. 7, p. 1339, doi. 10.1007/s10554-014-0459-z
- By:
- Publication type:
- Article
Progression of diffuse myocardial fibrosis assessed by cardiac magnetic resonance T₁ mapping.
- Published in:
- 2014
- By:
- Publication type:
- journal article
3.0-T whole-heart coronary magnetic resonance angiography: comparison of gadobenate dimeglumine and gadofosveset trisodium.
- Published in:
- International Journal of Cardiovascular Imaging, 2013, v. 29, n. 5, p. 1085, doi. 10.1007/s10554-013-0192-z
- By:
- Publication type:
- Article
Modified Look-Locker T<sub>1</sub> evaluation using Bloch simulations: Human and phantom validation.
- Published in:
- Magnetic Resonance in Medicine, 2013, v. 69, n. 2, p. 329, doi. 10.1002/mrm.24251
- By:
- Publication type:
- Article
Modified look-locker inversion recovery T1 mapping indices: assessment of accuracy and reproducibility between MRI scanners.
- Published in:
- 2013
- By:
- Publication type:
- Abstract
Modified look-locker inversion recovery T1 mapping indices: assessment of accuracy and reproducibility between magnetic resonance scanners.
- Published in:
- Journal of Cardiovascular Magnetic Resonance (BioMed Central), 2013, v. 15, n. 1, p. 64, doi. 10.1186/1532-429X-15-64
- By:
- Publication type:
- Article
Fast T1 mapping determined using incomplete inversion recovery look-locker 3D balanced SSFP acquisition and a simple two-parameter model fit.
- Published in:
- Journal of Magnetic Resonance Imaging, 2012, v. 35, n. 6, p. 1437, doi. 10.1002/jmri.23576
- By:
- Publication type:
- Article
Myocardial T1 mapping with MRI: Comparison of look-locker and MOLLI sequences.
- Published in:
- Journal of Magnetic Resonance Imaging, 2011, v. 34, n. 6, p. 1367, doi. 10.1002/jmri.22753
- By:
- Publication type:
- Article
Tracking accuracy of T2- and diffusion-weighted magnetic resonance imaging for infusate distribution by convection-enhanced delivery.
- Published in:
- Journal of Neurosurgery, 2011, v. 115, n. 3, p. 474, doi. 10.3171/2011.5.JNS11246
- By:
- Publication type:
- Article
T
- Published in:
- Magnetic Resonance in Medicine, 2011, v. 65, n. 5, p. 1407, doi. 10.1002/mrm.22716
- By:
- Publication type:
- Article
Whole-brain cerebral blood flow mapping using 3D echo planar imaging and pulsed arterial tagging.
- Published in:
- Journal of Magnetic Resonance Imaging, 2011, v. 33, n. 2, p. 287, doi. 10.1002/jmri.22437
- By:
- Publication type:
- Article
Modulated repetition time look-locker (MORTLL): A method for rapid high resolution three-dimensional T1 mapping.
- Published in:
- Journal of Magnetic Resonance Imaging, 2009, v. 30, n. 3, p. 640, doi. 10.1002/jmri.21842
- By:
- Publication type:
- Article
Median nerve cross-sectional area and MRI diffusion characteristics: normative values at the carpal tunnel.
- Published in:
- Skeletal Radiology, 2009, v. 38, n. 4, p. 355, doi. 10.1007/s00256-008-0626-1
- By:
- Publication type:
- Article
Design of a logarithmic k-space spiral trajectory.
- Published in:
- Magnetic Resonance in Medicine, 2001, v. 46, n. 6, p. 1130, doi. 10.1002/mrm.1309
- By:
- Publication type:
- Article
Elimination of Nyquist ghosts in MRI by using fast linogram imaging.
- Published in:
- 1997
- By:
- Publication type:
- journal article
A dual approach to linogram imaging for MRI.
- Published in:
- Magnetic Resonance in Medicine, 1997, v. 38, n. 2, p. 337, doi. 10.1002/mrm.1910380226
- By:
- Publication type:
- Article
Characterization of and correction for artifacts in linogram MRI.
- Published in:
- Magnetic Resonance in Medicine, 1997, v. 37, n. 2, p. 275, doi. 10.1002/mrm.1910370223
- By:
- Publication type:
- Article
Correction of motion artifacts in linogram and projection reconstruction MRI using geometry and consistency constraints.
- Published in:
- Medical Physics, 1996, v. 23, n. 2, p. 251, doi. 10.1118/1.597713
- By:
- Publication type:
- Article