Found: 93
Select item for more details and to access through your institution.
Quantitative magnetic resonance imaging of spinal cord microstructure in adults with cerebral palsy.
- Published in:
- 2021
- By:
- Publication type:
- journal article
Machine Learning and Multiparametric Brain MRI to Differentiate Hereditary Diffuse Leukodystrophy with Spheroids from Multiple Sclerosis.
- Published in:
- 2020
- By:
- Publication type:
- journal article
Topologically preserving straightening of spinal cord MRI.
- Published in:
- 2017
- By:
- Publication type:
- journal article
Validation of Rapid Magnetic Resonance Myelin Imaging in Multiple Sclerosis.
- Published in:
- 2020
- By:
- Publication type:
- journal article
Presymptomatic spinal cord pathology in c9orf72 mutation carriers: A longitudinal neuroimaging study.
- Published in:
- 2019
- By:
- Publication type:
- journal article
Involvement of spinal sensory pathway in ALS and specificity of cord atrophy to lower motor neuron degeneration.
- Published in:
- Amyotrophic Lateral Sclerosis & Frontotemporal Degeneration, 2013, v. 14, n. 1, p. 30, doi. 10.3109/17482968.2012.701308
- By:
- Publication type:
- Article
Quantitative magnetization transfer imaging made easy with q MTL ab: Software for data simulation, analysis, and visualization.
- Published in:
- Concepts in Magnetic Resonance. Part A: Bridging Education & Research, 2015, v. 44A, n. 5, p. 263, doi. 10.1002/cmr.a.21357
- By:
- Publication type:
- Article
Spinal cord evaluation in multiple sclerosis: clinical and radiological associations, present and future.
- Published in:
- Brain Communications, 2024, v. 6, n. 6, p. 1, doi. 10.1093/braincomms/fcae395
- By:
- Publication type:
- Article
Simultaneous Brain–Cervical Cord fMRI Reveals Intrinsic Spinal Cord Plasticity during Motor Sequence Learning.
- Published in:
- PLoS Biology, 2015, v. 13, n. 6, p. 1, doi. 10.1371/journal.pbio.1002186
- By:
- Publication type:
- Article
Gray Matter Alterations in Early and Late Relapsing-Remitting Multiple Sclerosis Evaluated with Synthetic Quantitative Magnetic Resonance Imaging.
- Published in:
- Scientific Reports, 2019, v. 9, n. 1, p. N.PAG, doi. 10.1038/s41598-019-44615-3
- By:
- Publication type:
- Article
Profiles of cortical inflammation in multiple sclerosis by 11 C-PBR28 MR-PET and 7 Tesla imaging.
- Published in:
- Multiple Sclerosis Journal, 2020, v. 26, n. 12, p. 1497, doi. 10.1177/1352458519867320
- By:
- Publication type:
- Article
Quantitative 7-Tesla Imaging of Cortical Myelin Changes in Early Multiple Sclerosis.
- Published in:
- Frontiers in Neurology, 2021, v. 12, p. 1, doi. 10.3389/fneur.2021.714820
- By:
- Publication type:
- Article
Generic acquisition protocol for quantitative MRI of the spinal cord.
- Published in:
- Nature Protocols, 2021, v. 16, n. 10, p. 4611, doi. 10.1038/s41596-021-00588-0
- By:
- Publication type:
- Article
AxonPacking: An Open-Source Software to Simulate Arrangements of Axons in White Matter.
- Published in:
- Frontiers in Neuroinformatics, 2017, v. 11, p. 1, doi. 10.3389/fninf.2017.00005
- By:
- Publication type:
- Article
AxonSeg: Open Source Software for Axon and Myelin Segmentation and Morphometric Analysis.
- Published in:
- Frontiers in Neuroinformatics, 2016, p. 1, doi. 10.3389/fninf.2016.00037
- By:
- Publication type:
- Article
Automatic Labeling of Vertebral Levels Using a Robust Template-Based Approach.
- Published in:
- International Journal of Biomedical Imaging, 2014, p. 1, doi. 10.1155/2014/719520
- By:
- Publication type:
- Article
Correction: Monitoring for myelopathic progression with multiparametric quantitative MRI.
- Published in:
- 2018
- By:
- Publication type:
- Correction Notice
Correction: Test-retest reliability of myelin imaging in the human spinal cord: Measurement errors versus region- and aging-induced variations.
- Published in:
- 2018
- By:
- Publication type:
- Correction Notice
Monitoring for myelopathic progression with multiparametric quantitative MRI.
- Published in:
- PLoS ONE, 2018, v. 13, n. 4, p. 1, doi. 10.1371/journal.pone.0195733
- By:
- Publication type:
- Article
Segmentation of the human spinal cord.
- Published in:
- MAGMA: Magnetic Resonance Materials in Physics, Biology & Medicine, 2016, v. 29, n. 2, p. 125, doi. 10.1007/s10334-015-0507-2
- By:
- Publication type:
- Article
RF shimming in the cervical spinal cord at 7 T.
- Published in:
- Magnetic Resonance in Medicine, 2024, v. 92, n. 6, p. 2392, doi. 10.1002/mrm.30225
- By:
- Publication type:
- Article
Calibration‐free parallel transmission of the cervical, thoracic, and lumbar spinal cord at 7T.
- Published in:
- Magnetic Resonance in Medicine, 2024, v. 92, n. 4, p. 1496, doi. 10.1002/mrm.30137
- By:
- Publication type:
- Article
Repeat it without me: Crowdsourcing the T<sub>1</sub> mapping common ground via the ISMRM reproducibility challenge.
- Published in:
- Magnetic Resonance in Medicine, 2024, v. 92, n. 3, p. 1115, doi. 10.1002/mrm.30111
- By:
- Publication type:
- Article
Shimming toolbox: An open‐source software toolbox for B0 and B1 shimming in MRI.
- Published in:
- Magnetic Resonance in Medicine, 2023, v. 89, n. 4, p. 1401, doi. 10.1002/mrm.29528
- By:
- Publication type:
- Article
Vendor‐neutral sequences and fully transparent workflows improve inter‐vendor reproducibility of quantitative MRI.
- Published in:
- Magnetic Resonance in Medicine, 2022, v. 88, n. 3, p. 1212, doi. 10.1002/mrm.29292
- By:
- Publication type:
- Article
Comparison of multicenter MRI protocols for visualizing the spinal cord gray matter.
- Published in:
- Magnetic Resonance in Medicine, 2022, v. 88, n. 2, p. 849, doi. 10.1002/mrm.29249
- By:
- Publication type:
- Article
Erratum to: Rapid simultaneous acquisition of macromolecular tissue volume, susceptibility, and relaxometry maps (Magn Reson Med. 2022;87:781‐790.).
- Published in:
- 2022
- By:
- Publication type:
- Correction Notice
Rapid simultaneous acquisition of macromolecular tissue volume, susceptibility, and relaxometry maps.
- Published in:
- Magnetic Resonance in Medicine, 2022, v. 87, n. 2, p. 781, doi. 10.1002/mrm.28995
- By:
- Publication type:
- Article
Real‐time correction of respiration‐induced distortions in the human spinal cord using a 24‐channel shim array.
- Published in:
- Magnetic Resonance in Medicine, 2018, v. 80, n. 3, p. 935, doi. 10.1002/mrm.27089
- By:
- Publication type:
- Article
Scan–rescan of axcaliber, macromolecular tissue volume, and g‐ratio in the spinal cord.
- Published in:
- Magnetic Resonance in Medicine, 2018, v. 79, n. 5, p. 2759, doi. 10.1002/mrm.26945
- By:
- Publication type:
- Article
A pneumatic phantom for mimicking respiration-induced artifacts in spinal MRI.
- Published in:
- Magnetic Resonance in Medicine, 2018, v. 79, n. 1, p. 600, doi. 10.1002/mrm.26679
- By:
- Publication type:
- Article
A 24-channel shim array for the human spinal cord: Design, evaluation, and application.
- Published in:
- Magnetic Resonance in Medicine, 2016, v. 76, n. 5, p. 1604, doi. 10.1002/mrm.26354
- By:
- Publication type:
- Article
Effect of respiration on the B<sub>0</sub> field in the human spinal cord at 3T.
- Published in:
- Magnetic Resonance in Medicine, 2014, v. 72, n. 6, p. 1629, doi. 10.1002/mrm.25075
- By:
- Publication type:
- Article
Nineteen-channel receive array and four-channel transmit array coil for cervical spinal cord imaging at 7T.
- Published in:
- 2014
- By:
- Publication type:
- Other
Nineteen-channel receive array and four-channel transmit array coil for cervical spinal cord imaging at 7T.
- Published in:
- Magnetic Resonance in Medicine, 2014, v. 72, n. 1, p. 291, doi. 10.1002/mrm.24911
- By:
- Publication type:
- Article
Fast diffusion tensor imaging and tractography of the whole cervical spinal cord using point spread function corrected echo planar imaging.
- Published in:
- Magnetic Resonance in Medicine, 2013, v. 69, n. 1, p. 144, doi. 10.1002/mrm.24235
- By:
- Publication type:
- Article
Accelerated diffusion spectrum imaging with compressed sensing using adaptive dictionaries.
- Published in:
- Magnetic Resonance in Medicine, 2012, v. 68, n. 6, p. 1747, doi. 10.1002/mrm.24505
- By:
- Publication type:
- Article
Accelerated diffusion spectrum imaging with compressed sensing using adaptive dictionaries.
- Published in:
- Magnetic Resonance in Medicine, 2012, v. 68, n. 6, p. spcone, doi. 10.1002/mrm.24583
- By:
- Publication type:
- Article
Imaging Mechanisms of Disease Progression in Multiple Sclerosis: Beyond Brain Atrophy.
- Published in:
- 2020
- By:
- Publication type:
- journal article
Author Correction: Open-access quantitative MRI data of the spinal cord and reproducibility across participants, sites and manufacturers.
- Published in:
- 2021
- By:
- Publication type:
- Correction Notice
Author Correction: Open-access quantitative MRI data of the spinal cord and reproducibility across participants, sites and manufacturers.
- Published in:
- 2021
- By:
- Publication type:
- Correction Notice
Open-access quantitative MRI data of the spinal cord and reproducibility across participants, sites and manufacturers.
- Published in:
- Scientific Data, 2021, v. 8, n. 1, p. 1, doi. 10.1038/s41597-021-00941-8
- By:
- Publication type:
- Article
Effectiveness of regional diffusion MRI measures in distinguishing multiple sclerosis abnormalities within the cervical spinal cord.
- Published in:
- Brain & Behavior, 2023, v. 13, n. 11, p. 1, doi. 10.1002/brb3.3159
- By:
- Publication type:
- Article
A simple and robust method for automating analysis of naïve and regenerating peripheral nerves.
- Published in:
- PLoS ONE, 2021, v. 16, n. 7, p. 1, doi. 10.1371/journal.pone.0248323
- By:
- Publication type:
- Article
NeoRS: A Neonatal Resting State fMRI Data Preprocessing Pipeline.
- Published in:
- Frontiers in Neuroinformatics, 2022, v. 16, p. 1, doi. 10.3389/fninf.2022.843114
- By:
- Publication type:
- Article
Microscopy-BIDS: An Extension to the Brain Imaging Data Structure for Microscopy Data.
- Published in:
- Frontiers in Neuroscience, 2022, v. 16, p. 1, doi. 10.3389/fnins.2022.871228
- By:
- Publication type:
- Article
Spinal diffusion tensor imaging: A comprehensive review with emphasis on spinal cord anatomy and clinical applications.
- Published in:
- Clinical Anatomy, 2015, v. 28, n. 1, p. 88, doi. 10.1002/ca.22349
- By:
- Publication type:
- Article
Spinal Cord Morphology in Degenerative Cervical Myelopathy Patients; Assessing Key Morphological Characteristics Using Machine Vision Tools.
- Published in:
- Journal of Clinical Medicine, 2021, v. 10, n. 4, p. 892, doi. 10.3390/jcm10040892
- By:
- Publication type:
- Article
Rapid, automated nerve histomorphometry through open-source artificial intelligence.
- Published in:
- Scientific Reports, 2022, v. 12, n. 1, p. 1, doi. 10.1038/s41598-022-10066-6
- By:
- Publication type:
- Article
Spinal Cord Segmentation by One Dimensional Normalized Template Matching: A Novel, Quantitative Technique to Analyze Advanced Magnetic Resonance Imaging Data.
- Published in:
- PLoS ONE, 2015, v. 10, n. 10, p. 1, doi. 10.1371/journal.pone.0139323
- By:
- Publication type:
- Article