Found: 58
Select item for more details and to access through your institution.
Mechanical extraction of implantable cardioverter-defibrillator leads with a dwell time of more than 10 years: insights from a single high-volume centre.
- Published in:
- EP: Europace, 2023, v. 25, n. 3, p. 1100, doi. 10.1093/europace/euac272
- By:
- Publication type:
- Article
Advances in Molecular Imaging in Infective Endocarditis.
- Published in:
- Vaccines, 2023, v. 11, n. 2, p. 420, doi. 10.3390/vaccines11020420
- By:
- Publication type:
- Article
Experience with transvenous lead extraction of His bundle pacing leads.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2024, v. 82, n. 9, p. 870, doi. 10.33963/v.phj.101556
- By:
- Publication type:
- Article
Implantacja nowego bezelektrodowego rozrusznika serca o aktywnej fiksacji u pacjentki po przezżylnym usunięciu układu stymulującego z powodów infekcyjnych.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2024, v. 82, p. 64
- By:
- Publication type:
- Article
Bezpieczeństwo onkologicznej terapii wiązką fotonową u pacjentów z ICD lub CRT-D -- ocena bezpośrednio po zakończonej radioterapii.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2024, v. 82, p. 5
- By:
- Publication type:
- Article
Single-chamber leadless pacemaker Aveir VR implantation: Pioneer experience in Poland. Insights and preliminary report from a multicenter national registry.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2024, v. 82, n. 7/8, p. 791, doi. 10.33963/v.phj.101020
- By:
- Publication type:
- Article
The effect of comprehensive management of heart failure in an adult with a systemic right ventricle.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2024, v. 82, n. 2, p. 235, doi. 10.33963/v.kp.98305
- By:
- Publication type:
- Article
Atrial pacemaker implantation in an adult patient with Fontan circulation and chronotropic insufficiency.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2023, v. 81, n. 12, p. 1298, doi. 10.33963/v.kp.98423
- By:
- Publication type:
- Article
A wearable cardioverter-defibrillator vest as a diagnostic and therapeutic tool after COVID-19.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2023, v. 81, n. 7/8, p. 800, doi. 10.33963/KP.a2023.0128
- By:
- Publication type:
- Article
Initial experience with transvenous lead extraction of His bundle pacing leads.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2023, v. 81, n. 7/8, p. 775, doi. 10.33963/kp.a2023.0125
- By:
- Publication type:
- Article
Cardiac pacing in patients with Fontan circulation: Further considerations. Authors' reply.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2022, v. 80, n. 5, p. 627, doi. 10.33963/KP.a2022.0096
- By:
- Publication type:
- Article
Atrioventricular sequential pacemaker implantation in an adult patient with a Fontan circulation.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2022, v. 80, n. 4, p. 497, doi. 10.33963/KP.a2022.0063
- By:
- Publication type:
- Article
His bundle pacing in a patient after heart transplant and complete atrioventricular block.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2021, v. 79, n. 1, p. 81, doi. 10.33963/KP.15681
- By:
- Publication type:
- Article
Znaczenie terapii przeciwdrobnoustrojowej poprzedzającej badanie scyntygrafii radioznakowanych leukocytów w diagnostyce infekcyjnego zapalenia wsierdzia.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2020, v. 78, p. 142
- By:
- Publication type:
- Article
Local infection associated with a nonfunctional lead in a patient with a VVI pacemaker: beyond the standard of care.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2020, v. 78, n. 1, p. 78, doi. 10.33963/KP.15044
- By:
- Publication type:
- Article
Permanent atrial fibrillation in patients with a dual-chamber pacemaker.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2019, v. 77, n. 12, p. 1140, doi. 10.33963/KP.14974
- By:
- Publication type:
- Article
Inflammatory markers in the diagnostic workup of pacemaker- and defibrillator-related infections in patients referred for transvenous lead extraction.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2019, v. 77, n. 10, p. 918, doi. 10.33963/KP.14934
- By:
- Publication type:
- Article
Years of life lost as a measure of premature death among dual-chamber pacemaker recipients from Małopolska Province.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2019, v. 77, n. 7/8, p. 683, doi. 10.33963/KP.14839
- By:
- Publication type:
- Article
Pol-CDRIE registry: 1-year observational data on patients hospitalized due to cardiac device-related infective endocarditis in Polish referential cardiology centers.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2019, v. 77, n. 5, p. 561, doi. 10.33963/KP.14811
- By:
- Publication type:
- Article
Complication of transvenous lead extraction: migration of the broken helix of an implantable cardioverter-defibrillator lead to the hepatic vein.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2018, v. 76, n. 11, p. 1574, doi. 10.5603/KP.2018.0223
- By:
- Publication type:
- Article
Diagnostic accuracy of radiolabelled leucocyte scintigraphy in cardiac device-related endocarditis.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2018, v. 76, p. 110
- By:
- Publication type:
- Article
Successful anti-tachycardia pacing of a temporary implantable cardioverter-defibrillator used in the treatment of an arrhythmic storm.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2018, v. 76, n. 9, p. 1380, doi. 10.5603/KP.2018.0189
- By:
- Publication type:
- Article
Lead-related complications after DDD pacemaker implantation.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2018, v. 76, n. 8, p. 1224, doi. 10.5603/KP.a2018.0089
- By:
- Publication type:
- Article
Dual-chamber ICD implantation via a persistent left superior vena cava -- use of an innominate vein for the placement of a right ventricular cardioverter-defibrillator lead implantation.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2017, v. 75, n. 2, p. 181, doi. 10.5603/KP.2017.0025
- By:
- Publication type:
- Article
Spontaneous dislocation of the endocardial lead into the left ventricle through the intraventricular septum.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2017, v. 75, n. 1, p. 79, doi. 10.5603/KP.2017.0004
- By:
- Publication type:
- Article
Successful transvenous extraction of an endocardial lead more than 35 years old using mechanical systems.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2016, v. 74, n. 11, p. 1357, doi. 10.5603/KP.2016.0161
- By:
- Publication type:
- Article
Lead-dependent infective endocarditis with a giant vegetation in the heart around an externalised VDD pacing lead. VDD lead externalisation in the course of tribological lead wear.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2015, v. 73, n. 5, p. 380, doi. 10.5603/KP.2015.0080
- By:
- Publication type:
- Article
Late complication of heart stimulation -- lead abrasion in pacemaker pocket.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2014, v. 72, n. 6, p. 555, doi. 10.5603/KP.2014.0123
- By:
- Publication type:
- Article
Heart perforation by pro-MRI right ventricular lead in a 26-year-old woman.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2014, v. 72, n. 5, p. 466, doi. 10.5603/KP.2014.0095
- By:
- Publication type:
- Article
Spaghetti-like leads in the heart -- a complication of permanent heart stimulation.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2014, v. 72, n. 3, p. 284, doi. 10.5603/KP.2014.0055
- By:
- Publication type:
- Article
Transvenous extraction of an eight-year-old ventricular lead accidentally implanted into the left ventricle.
- Published in:
- Polish Heart Journal / Kardiologia Polska, 2013, v. 71, n. 12, p. 1317, doi. 10.5603/KP.2013.0333
- By:
- Publication type:
- Article
Management of Arrhythmias and Conduction Disorders in Amyloid Cardiomyopathy.
- Published in:
- Journal of Clinical Medicine, 2024, v. 13, n. 11, p. 3088, doi. 10.3390/jcm13113088
- By:
- Publication type:
- Article
The usefulness of SPECT-CT with radioisotope-labeled leukocytes in diagnosing lead-dependent infective endocarditis.
- Published in:
- Advances in Clinical & Experimental Medicine, 2019, v. 28, n. 1, p. 113, doi. 10.17219/acem/92315
- By:
- Publication type:
- Article
Temporary external implantable cardioverter‐defibrillator as a bridge to reimplantation after infected device extraction.
- Published in:
- Journal of Arrhythmia, 2018, v. 34, n. 1, p. 77, doi. 10.1002/joa3.12026
- By:
- Publication type:
- Article
Infection of permanent pacing system with negative inflammatory markers.
- Published in:
- Polish Archives of Internal Medicine, 2014, v. 124, n. 5, p. 272
- By:
- Publication type:
- Article
Peri-electrode abscess in lead-dependent infective endocarditis resulting in high peri-interventional risk related to septic embolism.
- Published in:
- Polish Archives of Internal Medicine, 2013, v. 123, n. 6, p. 325
- By:
- Publication type:
- Article
Delayed perforation of the right ventricle by cardioverterdefibrillator lead -- safe transvenous lead extraction by mechanical systems.
- Published in:
- Advances in Interventional Cardiology / Postępy w Kardiologii Interwencyjnej, 2023, v. 19, n. 2, p. 192, doi. 10.5114/aic.2023.126180
- By:
- Publication type:
- Article
Tricuspid valve regurgitation in the presence of endocardial leads - an underestimated problem.
- Published in:
- Advances in Interventional Cardiology / Postępy w Kardiologii Interwencyjnej, 2017, v. 13, n. 2, p. 165, doi. 10.5114/pwki.2017.68073
- By:
- Publication type:
- Article
Contralateral pneumothorax after cardiac pacemaker implantation.
- Published in:
- 2015
- By:
- Publication type:
- Case Study
Thoracic impedance measurement in heart stimulation and cardiac arrhythmias.
- Published in:
- Pacing & Clinical Electrophysiology, 2021, v. 44, n. 1, p. 148, doi. 10.1111/pace.14121
- By:
- Publication type:
- Article
Transvenous extraction of very old (over 20‐year‐old) pacemaker leads using mechanical systems: Effectiveness and safety.
- Published in:
- Pacing & Clinical Electrophysiology, 2019, v. 42, n. 7, p. 998, doi. 10.1111/pace.13714
- By:
- Publication type:
- Article
Cardiac resynchronization therapy with His bundle pacing.
- Published in:
- Pacing & Clinical Electrophysiology, 2019, v. 42, n. 3, p. 374, doi. 10.1111/pace.13611
- By:
- Publication type:
- Article
Analysis of electrical lead failures in patients referred for transvenous lead extraction procedures.
- Published in:
- Pacing & Clinical Electrophysiology, 2018, v. 41, n. 9, p. 1217, doi. 10.1111/pace.13463
- By:
- Publication type:
- Article
Transvenous extraction of His bundle pacing lead: New challenge in the field of lead extraction.
- Published in:
- Cardiology Journal, 2019, v. 26, n. 6, p. 805, doi. 10.5603/CJ.2019.0120
- By:
- Publication type:
- Article
Association of selected factors with long-term prognosis and mortality after dual-chamber pacemaker implant.
- Published in:
- Cardiology Journal, 2019, v. 26, n. 6, p. 717, doi. 10.5603/CJ.a2018.0093
- By:
- Publication type:
- Article
Diagnostic dilemma regarding the extent of implantable cardioverter-defibrillator infection: Pocket infection alone or pocket infection with concomitant lead-dependent infective endocarditis?
- Published in:
- Cardiology Journal, 2018, v. 25, n. 1, p. 146, doi. 10.5603/CJ.2018.0012
- By:
- Publication type:
- Article
Complications of permanent cardiac pacing in patients with persistent left superior vena cava.
- Published in:
- Cardiology Journal, 2014, v. 21, n. 2, p. 128, doi. 10.5603/CJ.a2014.0006
- By:
- Publication type:
- Article
Safety and effectiveness of transvenous lead extraction in elderly patients.
- Published in:
- Cardiology Journal, 2014, v. 21, n. 1, p. 47, doi. 10.5603/CJ.a2013.0084
- By:
- Publication type:
- Article
The role of 99mTc-HMPAO-labelled white blood cell scintigraphy in the diagnosis of cardiac device-related infective endocarditis.
- Published in:
- European Heart Journal - Cardiovascular Imaging, 2020, v. 21, n. 9, p. 1022, doi. 10.1093/ehjci/jez257
- By:
- Publication type:
- Article
99mTc-HMPAO-labeled leukocyte SPECT/CT and transthoracic echocardiography diagnostic value in infective endocarditis.
- Published in:
- 2019
- By:
- Publication type:
- journal article