The problem of yellow plume exists in most heavy-duty gas turbine units under start-up and low load conditions. How to suppress the yellow plume is a difficult problem in gas turbine power plants. It is judged that yellow plume is caused by the high NO2 concentration in flue gas. From the point of view of mechanism research, this study analyzed the causes of yellow plume by numerical simulation combined with experimental research; obtained influence factors of the conversion of NO into NO2; analyzed the degree of influence of these factors on the formation of yellow plume; verified the results through on-site measurement of a 6FA gas turbine unit; and finally proposed the countermeasures to suppress yellow plume from the gas turbine side and the heat recovery steam generator (HRSG) side.