EBSCO Logo
Connecting you to content on EBSCOhost
Results
Title

CT-based temperature monitoring during hepatic RF ablation: Feasibility in an animal model.

Authors

Bruners, Philipp; Pandeya, Ganga D.; Levit, Elena; Roesch, Eva; Penzkofer, Tobias; Isfort, Peter; Schmidt, Bernhardt; greuter, Marcel J.W.; Oudkerk, Matthijs; Schmitz-Rode, Thomas; Kuhl, Christiane K.; Mahnken, Andreas H.

Abstract

Purpose: The aim of this paper was to establish non-invasive CT-based temperature monitoring during hepatic radiofrequency (RF) ablation in an ex vivo porcine model followed by transfer of the technique into a feasibility in vivo experiment. Materials and methods: Bipolar RF ablations were performed in 10 specimens of porcine liver. Parallel to the needle-shaped RF applicator three optical temperature probes were inserted into the liver specimens at fixed distances of 5, 10 and 15 mm from the RF probe. During energy application (20 W) unenhanced sequential MSCT scans were acquired using the following scan protocol: 140 kV tube voltage, 300 mAs/rotation tube current time product, collimation 24 × 1.2 mm, rotation time 0.5 s. Axial image data was reconstructed using a soft tissue convolution kernel. Temperature data was recorded during every CT scan. Using a circular 0.5 cm2 region of interest local CT values were measured at the tips of the temperature probes and matched with the measured temperatures. Regression analysis was performed to analyse the relationship between local temperatures and CT values for each temperature probe position. Furthermore, the same experimental design was used in four anaesthetised female pigs in order to investigate the potential of this technique for an in vivo application. Results: A negative correlation was found for the relationship between temperature and CT value. Regression coefficients were −0.44 (5 mm), −0.35 (10 mm) and −0.37 (15 mm) for ex vivo data. Analysis of in vivo experiments showed regression coefficients between −0.025 and −0.434. Conclusion: Multislice computed tomography is able to depict temperature changes in liver tissue during RFA.

Subjects

MEDICAL radiography; MULTIVARIATE analysis; DIAGNOSTIC imaging; RADIO frequency; TOMOGRAPHY

Publication

International Journal of Hyperthermia, 2012, Vol 28, Issue 1, p55

ISSN

0265-6736

Publication type

Academic Journal

DOI

10.3109/02656736.2011.619155