EBSCO Logo
Connecting you to content on EBSCOhost
Results
Title

AACC Guidance Document on Biotin Interference in Laboratory Tests.

Authors

Danni Li; Ferguson, Angela; Cervinski, Mark A.; Lynch, Kara L.; Kyle, Patrick B.

Abstract

Background: Laboratory tests that use streptavidin--biotin binding mechanisms have the potential to be affected by high circulating biotin concentrations, which would produce positive and negative interference in biotinylated competitive and noncompetitive (sandwich) immunoassays, respectively. Consumption of high-dose biotin supplements for cosmetic or health-related reasons has drawn attention to biotin interference in clinical laboratory tests. Case reports and in vivo studies show that ingestion of supplemental biotin can cause clinically signifi- cant errors in select biotinylated immunoassays. Content: This AACC Academy document is intended to provide guidance to laboratorians and clinicians for preventing, identifying, and dealing with biotin interference. In vivo and in vitro spiking studies have demonstrated that biotin concentrations required to cause interference vary by test and by manufacturer. This document includes discussion of biotin's mechanisms for interference in immunoassays, pharmacokinetics, and results of in vitro and in vivo studies and cites examples of assays known to be affected by high biotin concentrations. This document also provides guidance recommendations intended to assist laboratories and clinicians in identifying and addressing biotin interference in laboratory testing. Summary: The recent increase in the use of high-dose biotin supplements requires laboratorians and clinicians to be mindful of the potential for biotin interference in biotinylated immunoassay-based laboratory tests. Laboratories, clinicians, regulators, and patients should work together to ensure accurate laboratory results. Laboratories have several options for identifying suspected biotin interference in specimens. Alternatively, the relatively fast elimination of biotin allows the potential for rapid follow-up specimen analysis if necessary.

Subjects

TESTING laboratories; BIOTIN; STREPTAVIDIN; IMMUNOASSAY; PHARMACOKINETICS; AMERICAN Association for Clinical Chemistry

Publication

Journal of Applied Laboratory Medicine, 2020, Vol 5, Issue 3, p575

ISSN

2475-7241

Publication type

Academic Journal

DOI

10.1093/jalm/jfz010

EBSCO Connect | Privacy policy | Terms of use | Copyright | Manage my cookies
Journals | Subjects | Sitemap
© 2025 EBSCO Industries, Inc. All rights reserved