EBSCO Logo
Connecting you to content on EBSCOhost
Results
Title

Pressurized Wideband Absorbance Findings in Healthy Neonates: A Preliminary Study.

Authors

Wali, Hamzah A.; Mazlan, Rafidah; Kei, Joseph

Abstract

Purpose: The present study aimed to establish normative data for wideband absorbance (WBA) measured at tympanometric peak pressure (TPP) and 0 daPa and to assess the test--retest reliability of both measurements in healthy neonates. Method: Participants of this cross-sectional study included 99 full-term neonates (165 ears) with mean chronological age of 46.7 hrs (SD = 26.3 hrs). Of the 99 neonates, 58 were Malay, 28 were Indian and 13 were Chinese. The neonates who passed high-frequency (1 kHz) tympanometry, acoustic stapedial reflex and distortion product otoacoustic emission screening tests were assessed using a pressurized WBA test (wideband tympanometry). To reduce the number of measurement points, the WBA responses were averaged to 16 one-third octave frequency bands from 0.25 to 8 kHz. A mixed-model analysis of variance was applied to the data to investigate the effects of frequency, ear, gender, and ethnicity on WBA. The analysis of variance was also used to compare between WBA measured at TPP and 0 daPa. An interclass correlation coefficient test was applied at each of the 16 frequency bands to measure the test--retest reliability of WBA at TPP and 0 daPa. Results: Both WBA measurements at TPP and 0 daPa exhibited a multipeaked pattern with 2 maxima at 1.25--1.6 kHz and 6.3 kHz and 2 minima at 0.5 and 4 kHz. The mean WBA measured at TPP was significantly higher than that measured at 0 daPa at 0.25, 0.4, 0.5, 1.25, and 1.6 kHz only. A normative data set was developed for absorbance at TPP and at 0 daPa. There was no significant effect of ethnicity, gender, and ear on both measurements of WBA. The test--retest reliability of WBA at TPP and 0 daPa was high with the interclass correlation coefficient ranging from 0.77 to 0.97 across the frequencies. Conclusions: Normative data of WBA measured at TPP and 0 daPa for neonates were provided in the present study. Although WBA at TPP was slightly higher than the WBA measured at 0 daPa at some frequencies below 2 kHz, the WBA patterns of the 2 measurements were nearly identical. Moreover, the test--retest reliability of both WBA measurements was high.

Subjects

MALAYSIA; NEWBORN infant physiology; IMPEDANCE audiometry; HEARING -- Physiological aspects; INFANT development; HEARING disorder diagnosis; MIDDLE ear physiology; ANALYSIS of variance; HEARING; STATISTICS; DATA analysis; STATISTICAL reliability; CROSS-sectional method; DATA analysis software; DESCRIPTIVE statistics; ONE-way analysis of variance; INTRACLASS correlation; CHILDREN

Publication

Journal of Speech, Language & Hearing Research, 2017, Vol 60, Issue 10, p2965

ISSN

1092-4388

Publication type

Academic Journal

DOI

10.1044/2017_JSLHR-H-17-0120

EBSCO Connect | Privacy policy | Terms of use | Copyright | Manage my cookies
Journals | Subjects | Sitemap
© 2025 EBSCO Industries, Inc. All rights reserved