We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Malpositioning of patient-specific instruments within the possible degrees of freedom in high-tibial osteotomy has no considerable influence on mechanical leg axis correction.
- Authors
Jud, Lukas; Fürnstahl, Philipp; Vlachopoulos, Lazaros; Götschi, Tobias; Leoty, Laura Catherine; Fucentese, Sandro F.
- Abstract
Purpose: Patient-specific instruments (PSIs) are helpful tools in high tibial osteotomy (HTO) in patients with symptomatic varus malalignment of the mechanical leg axis. However, the precision of HTO can decrease with malpositioned PSI. This study investigates the influence of malpositioned PSI on axis correction, osteotomy, and implant placement.Methods: With a mean three-dimensional (3D) model (0.8° varus), PSI-navigated HTOs were computer simulated. Two different guide designs, one with stabilising hooks and one without, were used. By adding rotational and translational offsets of different degrees, wrong placements of PSI were simulated. After 5° valgisation of the postoperative mechanical axis, the distance between joint-plane and osteotomy screws, respectively, were measured. The same simulations were performed in a patient with varus deformity (7.4° varus).Results: In the mean 3D model, the postoperative mechanical axis was within 3.9°-4.5° valgus with mean value of 4.1° ± 0.1° (correct axis 4.2° valgus). Surgical failure concerning osteotomy occurred in 17 of 76 HTOs. Significantly safer screw placement was observed using PSI with stabilising hooks (p = 0.012). In the case of the 3D model with 7.4° varus deformity, the postoperative mechanical axis was within 3.2°-3.9° valgus with mean value of 3.8° ± 0.2° (correct axis 3.9° valgus). Surgical failure concerning osteotomy occurred in 3 of 38 HTOs. Screws were always within the safety distance.Conclusion: The clinical relevance of the presented study is that malpositioning of a PSI within the possible degrees of freedom does not have a relevant influence on the axis correction. The most vulnerable plane for surgical failure is the sagittal plane, wherefore the treating surgeon should verify correct guide placement to prevent surgical failure, particularly in this plane.Level Of Evidence: III.
- Subjects
PATIENTS; OSTEOTOMY; SCREWS; ANATOMICAL planes; SURGEONS; TIBIA surgery; KNEE diseases; COMPUTER simulation; COMPUTER-assisted surgery; TOTAL knee replacement; THREE-dimensional imaging; BONE screws; OSTEOARTHRITIS; POSTOPERATIVE period
- Publication
Knee Surgery, Sports Traumatology, Arthroscopy, 2020, Vol 28, Issue 5, p1356
- ISSN
0942-2056
- Publication type
Academic Journal
- DOI
10.1007/s00167-019-05432-3