We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
In-situ calibration of boiler instrumentation using analytic redundancy.
- Authors
Guanghua Wei; Mingsheng Liu; David E. Claridge
- Abstract
This paper presents a broadly useful diagnostic methodology, which engineers and plant managers can use to detect system faults and find the in-situ operating characteristics of boilers when some metered data are either missing or obviously erroneous. The methodology is able to analyse conflicting measurements and utilize analytic redundancy (AR) to deduce the measurement or measurements that are substantially in error without shutting down the plant and recalibrating all instrumentation. The application of the AR technique in evaluating boiler performance is presented through a case study. Copyright © 2001 John Wiley & Sons, Ltd.
- Subjects
BOILERS; REDUNDANCY in engineering; PRESSURE vessels; CALIBRATION
- Publication
International Journal of Energy Research, 2001, Vol 25, Issue 5, p375
- ISSN
0363-907X
- Publication type
Academic Journal
- DOI
10.1002/er.684