Found: 33
Select item for more details and to access through your institution.
Observing the Biofilm Matrix of Staphylococcus epidermidis ATCC 35984 Grown Using the CDC Biofilm Reactor.
- Published in:
- Microscopy & Microanalysis, 2010, v. 16, n. 2, p. 143, doi. 10.1017/S143192760999136X
- By:
- Publication type:
- Article
A Review of the Collagen Orientation in the Articular Cartilage.
- Published in:
- Cartilage, 2021, v. 13, p. 367S, doi. 10.1177/1947603520988770
- By:
- Publication type:
- Article
Experimental model of biofilm implant-related osteomyelitis to test combination biomaterials using biofilms as initial inocula.
- Published in:
- Journal of Biomedical Materials Research, Part A, 2012, v. 100A, n. 7, p. 1888, doi. 10.1002/jbm.a.34123
- By:
- Publication type:
- Article
A Modified CDC Biofilm Reactor to Produce Mature Biofilms on the Surface of PEEK Membranes for an In Vivo Animal Model Application.
- Published in:
- Current Microbiology, 2011, v. 62, n. 6, p. 1657, doi. 10.1007/s00284-011-9908-2
- By:
- Publication type:
- Article
Characterization of Bacterial Isolates Collected from a Sheep Model of Osseointegration.
- Published in:
- Current Microbiology, 2010, v. 61, n. 6, p. 574, doi. 10.1007/s00284-010-9655-9
- By:
- Publication type:
- Article
Ability of a wash regimen to remove biofilm from the exposed surface of materials used in osseointegrated implants.
- Published in:
- Journal of Orthopaedic Research, 2019, v. 37, n. 1, p. 248, doi. 10.1002/jor.24161
- By:
- Publication type:
- Article
Bone ingrowth comparison of irregular titanium and cobalt‐chromium coatings in a translational cancellous bone model.
- Published in:
- Journal of Biomedical Materials Research, Part B: Applied Biomaterials, 2020, v. 108, n. 4, p. 1626, doi. 10.1002/jbm.b.34509
- By:
- Publication type:
- Article
Transcortical or intracondylar? Which model is accurate for predicting biomaterial attachment in total joint replacement?
- Published in:
- Journal of Biomedical Materials Research, Part B: Applied Biomaterials, 2018, v. 106, n. 2, p. 578, doi. 10.1002/jbm.b.33873
- By:
- Publication type:
- Article
Model development for determining the efficacy of a combination coating for the prevention of perioperative device related infections: A pilot study.
- Published in:
- Journal of Biomedical Materials Research, Part B: Applied Biomaterials, 2013, v. 101B, n. 7, p. 1143, doi. 10.1002/jbm.b.32924
- By:
- Publication type:
- Article
Characterization of a novel active release coating to prevent biofilm implant-related infections.
- Published in:
- Journal of Biomedical Materials Research, Part B: Applied Biomaterials, 2013, v. 101B, n. 6, p. 1078, doi. 10.1002/jbm.b.32918
- By:
- Publication type:
- Article
An evaluation of electrical stimulation for improving periprosthetic attachment.
- Published in:
- Journal of Biomedical Materials Research, Part B: Applied Biomaterials, 2011, v. 97B, n. 1, p. 190, doi. 10.1002/jbm.b.31803
- By:
- Publication type:
- Article
Assessing peri‐implant tissue infection prevention in a percutaneous model.
- Published in:
- Journal of Biomedical Materials Research, Part B: Applied Biomaterials, 2010, v. 92B, n. 2, p. 397, doi. 10.1002/jbm.b.31528
- By:
- Publication type:
- Article
Remodeling capacity of calcified fibrocartilage of the hip.
- Published in:
- Anatomical Record: Advances in Integrative Anatomy & Evolutionary Biology, 2004, v. 279A, n. 2, p. 736, doi. 10.1002/ar.a.20066
- By:
- Publication type:
- Article
Regional differences in cortical bone organization and microdamage prevalence in Rocky Mountain mule deer.
- Published in:
- Anatomical Record: Advances in Integrative Anatomy & Evolutionary Biology, 2003, v. 274A, n. 1, p. 837, doi. 10.1002/ar.a.10102
- By:
- Publication type:
- Article
Variation in bone response to the placement of percutaneous osseointegrated endoprostheses: A 24-month follow-up in sheep.
- Published in:
- PLoS ONE, 2019, v. 14, n. 10, p. 1, doi. 10.1371/journal.pone.0221850
- By:
- Publication type:
- Article
Mineral content changes in bone associated with damage induced by the electron beam.
- Published in:
- Scanning, 2005, v. 27, n. 5, p. 240, doi. 10.1002/sca.4950270504
- By:
- Publication type:
- Article
Thermal effects of the electron beam and implications of surface damage in the analysis of bone tissue.
- Published in:
- Scanning, 2000, v. 22, n. 4, p. 243, doi. 10.1002/sca.4950220403
- By:
- Publication type:
- Article
Influence of topography and specimen preparation on backscattered electron images of bone.
- Published in:
- Scanning, 1999, v. 21, n. 6, p. 379, doi. 10.1002/sca.4950210604
- By:
- Publication type:
- Article
Errors in quantitative backscattered electron analysis of bone standardized by energy-dispersive x-ray spectrometry.
- Published in:
- Scanning, 1998, v. 20, n. 7, p. 527, doi. 10.1002/sca.1998.4950200708
- By:
- Publication type:
- Article
The Significance of Calcified Fibrocartilage on the Cortical Endplate of the Translational Sheep Spine Model.
- Published in:
- Anatomical Record: Advances in Integrative Anatomy & Evolutionary Biology, 2013, v. 296, n. 5, p. 736, doi. 10.1002/ar.22683
- By:
- Publication type:
- Article
Cortical Bone Response to the Presence of Load-Bearing Percutaneous Osseointegrated Prostheses.
- Published in:
- Anatomical Record: Advances in Integrative Anatomy & Evolutionary Biology, 2012, v. 295, n. 9, p. 1437, doi. 10.1002/ar.22533
- By:
- Publication type:
- Article
Characterization of the Anchoring Morphology and Mineral Content of the Anterior Cruciate and Medial Collateral Ligaments of the Knee.
- Published in:
- Anatomical Record: Advances in Integrative Anatomy & Evolutionary Biology, 2011, v. 294, n. 5, p. 831, doi. 10.1002/ar.21374
- By:
- Publication type:
- Article
Cement lines of secondary osteons in human bone are not mineral-deficient: New data in a historical perspective.
- Published in:
- Anatomical Record: Advances in Integrative Anatomy & Evolutionary Biology, 2005, v. 286A, n. 1, p. 781, doi. 10.1002/ar.a.20214
- By:
- Publication type:
- Article
Age-Related mineralization heterogeneity changes in trabecular bone of the proximal femur.
- Published in:
- Anatomical Record: Advances in Integrative Anatomy & Evolutionary Biology, 2004, v. 281A, n. 2, p. 1296, doi. 10.1002/ar.a.20079
- By:
- Publication type:
- Article
The Road to Recovery and Rehabilitation for Injured Service Members with Limb Loss: A Focus on Iraq and Afghanistan.
- Published in:
- U.S. Army Medical Department Journal, 2010, p. 31
- By:
- Publication type:
- Article
Strain‐mode‐specific mechanical testing and the interpretation of bone adaptation in the deer calcaneus.
- Published in:
- Journal of Anatomy, 2024, v. 244, n. 3, p. 411, doi. 10.1111/joa.13971
- By:
- Publication type:
- Article
Advancing the deer calcaneus model for bone adaptation studies: ex vivo strains obtained after transecting the tension members suggest an unrecognized important role for shear strains.
- Published in:
- Journal of Anatomy, 2019, v. 234, n. 1, p. 66, doi. 10.1111/joa.12905
- By:
- Publication type:
- Article
Sealed osteons in animals and humans: low prevalence and lack of relationship with age.
- Published in:
- Journal of Anatomy, 2018, v. 232, n. 5, p. 824, doi. 10.1111/joa.12786
- By:
- Publication type:
- Article
Do regional modifications in tissue mineral content and microscopic mineralization heterogeneity adapt trabecular bone tracts for habitual bending? Analysis in the context of trabecular architecture of deer calcanei.
- Published in:
- Journal of Anatomy, 2012, v. 220, n. 3, p. 242, doi. 10.1111/j.1469-7580.2011.01470.x
- By:
- Publication type:
- Article
Relationships of loading history and structural and material characteristics of bone: Development of the mule deer calcaneus (This article is a US Government work and, as such, is in the public domain in the United States of America.).
- Published in:
- Journal of Morphology, 2004, v. 259, n. 3, p. 281, doi. 10.1002/jmor.10167
- By:
- Publication type:
- Article
Developing a Quantitative Measurement System for Assessing Heterotopic Ossification and Monitoring the Bioelectric Metrics from Electrically Induced Osseointegration in the Residual Limb of Service Members.
- Published in:
- Annals of Biomedical Engineering, 2010, v. 38, n. 9, p. 2968, doi. 10.1007/s10439-010-0050-2
- By:
- Publication type:
- Article
Backscattered Electron Imaging: The Role in Calcified Tissue and Implant Analysis.
- Published in:
- Journal of Biomaterials Applications, 1990, v. 5, n. 1, p. 56, doi. 10.1177/088532829000500105
- By:
- Publication type:
- Article
Efficacy of a porous-structured titanium subdermal barrier for preventing infection in percutaneous osseointegrated prostheses.
- Published in:
- Journal of Orthopaedic Research, 2012, v. 30, n. 8, p. 1304, doi. 10.1002/jor.22081
- By:
- Publication type:
- Article