Prior to immersion gold plating, the electrolessly plated Ni coating or Pd coating was modified with a solution composed of chloric acid and copper(II) chloride, a solution composed sulfuric acid and hydrogen peroxide, or a cerium(IV) sulfate solution. The effects of the solution composition, temperature, and time for the modification on the thickness of Au coating (i.e. Au deposition rate) were studied. The optimized modification temperature and time were 50 °C and 4 min, respectively. The micromorphologies and phase structure of Au coating deposited on the Ni coating modified with different solutions were compared. The results showed that the surface modification of Ni coating had not only no corrosive attack to itself, but also no impact on the preferred orientation of Au coating, while had certain influence on the average grain size of Au coating. The deposition of gold during immersion plating could be increased significantly if the Ni coating was modified with the solution composed of chloric acid and copper(II) chloride or the cerium(IV) sulfate solution.