We found a match
Your institution may have rights to this item. Sign in to continue.
- Title
Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique.
- Authors
Katsura, Masaki; Matsuda, Izuru; Akahane, Masaaki; Sato, Jiro; Akai, Hiroyuki; Yasaka, Koichiro; Kunimatsu, Akira; Ohtomo, Kuni
- Abstract
Objectives: To prospectively evaluate dose reduction and image quality characteristics of chest CT reconstructed with model-based iterative reconstruction (MBIR) compared with adaptive statistical iterative reconstruction (ASIR). Methods: One hundred patients underwent reference-dose and low-dose unenhanced chest CT with 64-row multidetector CT. Images were reconstructed with 50 % ASIR-filtered back projection blending (ASIR50) for reference-dose CT, and with ASIR50 and MBIR for low-dose CT. Two radiologists assessed the images in a blinded manner for subjective image noise, artefacts and diagnostic acceptability. Objective image noise was measured in the lung parenchyma. Data were analysed using the sign test and pair-wise Student's t-test. Results: Compared with reference-dose CT, there was a 79.0 % decrease in dose-length product with low-dose CT. Low-dose MBIR images had significantly lower objective image noise (16.93 ± 3.00) than low-dose ASIR (49.24 ± 9.11, P < 0.01) and reference-dose ASIR images (24.93 ± 4.65, P < 0.01). Low-dose MBIR images were all diagnostically acceptable. Unique features of low-dose MBIR images included motion artefacts and pixellated blotchy appearances, which did not adversely affect diagnostic acceptability. Conclusion: Diagnostically acceptable chest CT images acquired with nearly 80 % less radiation can be obtained using MBIR. MBIR shows greater potential than ASIR for providing diagnostically acceptable low-dose CT images without severely compromising image quality. Key Points: • Model-based iterative reconstruction (MBIR) creates high-quality low-dose CT images. • MBIR significantly improves image noise and artefacts over adaptive statistical iterative techniques. • MBIR shows greater potential than ASIR for diagnostically acceptable low-dose CT. • The prolonged processing time of MBIR may currently limit its routine use in clinical practice.
- Subjects
IMAGE quality in radiography; RADIATION doses; TOMOGRAPHY; CHEST X rays; DIAGNOSTIC imaging; RADIOLOGISTS
- Publication
European Radiology, 2012, Vol 22, Issue 8, p1613
- ISSN
0938-7994
- Publication type
Article
- DOI
10.1007/s00330-012-2452-z