We found a match
Your institution may have rights to this item. Sign in to continue.
- Title
Serum Pepsinogens Combined with New Biomarkers Testing Using Chemiluminescent Enzyme Immunoassay for Non-Invasive Diagnosis of Atrophic Gastritis: A Prospective, Multicenter Study.
- Authors
Chapelle, Nicolas; Osmola, Malgorzata; Martin, Jérôme; Blin, Justine; Leroy, Maxime; Jirka, Iva; Moussata, Driffa; Lamarque, Dominique; Olivier, Raphael; Tougeron, David; Hay-Lombardie, Anne; Bigot-Corbel, Edith; Masson, Damien; Mosnier, Jean-François; Matysiak-Budnik, Tamara
- Abstract
Background: Analysis of serum biomarkers for the assessment of atrophic gastritis (AG), a gastric precancerous lesion, is of growing interest for identification of patients at increased risk of gastric cancer. The aim was to analyze the diagnostic performance of serum pepsinogen testing using another method, chemiluminescent enzyme immunoassay (CLEIA), as well as of other new potential biomarkers. Material and Methods: The sera of patients considered at increased risk of gastric cancer and undergoing upper endoscopy collected in our previous prospective, multicenter study were tested for pepsinogen I (PGI) and II (PGII), interleukin-6 (IL-6), human epididymal protein 4 (HE-4), adiponectin, ferritin and Krebs von den Lungen (KL-6) using the CLEIA. The diagnostic performance for the detection of AG was calculated by taking histology as the reference. Results: In total, 356 patients (162 men (46%); mean age 58.6 (±14.2) years), including 152 with AG, were included. For the detection of moderate to severe corpus AG, sensitivity and specificity of the pepsinogen I/II ratio were of 75.0% (95%CI 57.8–87.9) and 92.6% (88.2–95.8), respectively. For the detection of moderate to severe antrum AG, sensitivity of IL-6 was of 72.2% (95%CI 46.5–90.3). Combination of pepsinogen I/II ratio or HE-4 showed a sensitivity of 85.2% (95%CI 72.9–93.4) for the detection of moderate to severe AG at any location. Conclusion: This study shows that PG testing by CLEIA represents an accurate assay for the detection of corpus AG. Additionally, IL-6 and HE-4 may be of interest for the detection of antrum AG. Mini-abstract: Pepsinogens testing by chemiluminescent enzyme immunoassay is accurate for the detection of corpus atrophic gastritis. IL-6 and HE-4 maybe of interest for the detection of antrum atrophic gastritis.
- Subjects
ENZYME-linked immunosorbent assay; FERRITIN; BIOMARKERS; DIAGNOSIS; PEPSINOGEN; DISEASE risk factors; ATROPHIC gastritis
- Publication
Diagnostics (2075-4418), 2022, Vol 12, Issue 3, p695
- ISSN
2075-4418
- Publication type
Article
- DOI
10.3390/diagnostics12030695