- Title
Erythrocytenzahlbestimmung: Vergleich von Impedanz- und Trübungsmessung bei ausgewählten Krankheitsbildern.
- Authors
Quade, A.; Baudach, A.; Bittner, S.; Carl, B.; Steinhäuser, I.; Rücker, A. v.; Heller, S.
- Abstract
Determination of erythrocyte concentration using easy to manage turbidimetric instruments should help general practitioners make yes/no decisions in the first stage of diagnostics. The laboratories of five hematologic centers have demonstrated the unsuitability of turbidimetric instruments for this purpose. Up to 50% false normal erythrocyte concentrations were found in a study of patients with selected hematologic diseases.
- Publication
Journal of Laboratory Medicine / Laboratoriums Medizin, 1995, Vol 19, Issue 1-12, p328
- ISSN
0342-3026
- Publication type