- Title
Method-specific performance of vancomycin MIC susceptibility tests in predicting mortality of patients with methicillin-resistant Staphylococcus aureus bacteraemia.
- Authors
Chen, Shey-Ying; Liao, Chun-Hsing; Wang, Jiun-Ling; Chiang, Wen-Chu; Lai, Mei-Shu; Chie, Wei-Chu; Chang, Shan-Chwen; Hsueh, Po-Ren
- Abstract
Objectives Emerging evidence shows that methicillin-resistant Staphylococcus aureus (MRSA) infections caused by isolates with higher vancomycin MICs within the susceptibility range are associated with adverse outcomes. No study, however, has examined different susceptibility tests in predicting treatment outcomes of MRSA infections. Methods This retrospective cohort study included 393 patients with MRSA bacteraemia. Vancomycin MICs for all MRSA isolates were determined simultaneously by agar dilution and the Etest, and using the MicroScan, VITEK-2 and Phoenix automated systems, and categorized into low- and high-MIC isolates at a breakpoint of ≥2 mg/L. The essential and categorical agreement between testing methods was compared. The method-specific ability to predict in-hospital mortality was examined by multivariate logistic regression analysis controlling for other potential confounders using clinical data from 310 vancomycin-treated MRSA bacteraemia patients. Results The agar dilution, Etest, MicroScan, VITEK-2 and Phoenix methods assessed 14.2% (56/393), 9.7% (38/393), 28.8% (113/393), 22.6% (89/393) and 3.1% (12/393) of MRSA isolates as having high (≥2 mg/L) vancomycin MICs. The essential and categorical agreement between testing methods ranged from 98.5% to 100% and from 73.8% to 91.9%, respectively. High vancomycin MICs for isolates determined using agar dilution and the Etest independently predicted mortality when controlling for confounding factors [adjusted OR, 2.321; 95% CI, 1.160–4.641; and adjusted OR, 3.121; 95% CI, 1.293–7.536, respectively]. High vancomycin MICs determined using all three automated systems failed to predict mortality. Conclusions Vancomycin MICs generated by the agar dilution and Etest methods, but not the automated systems, independently predicted mortality among vancomycin-treated MRSA bacteraemia patients. Clinicians should incorporate this information with clinical assessment for decisions on appropriate anti-MRSA treatment.
- Subjects
VANCOMYCIN; METHICILLIN-resistant staphylococcus aureus; MICROBIAL sensitivity tests; DRUG side effects; SIDE effects of anti-infective agents
- Publication
Journal of Antimicrobial Chemotherapy (JAC), 2014, Vol 69, Issue 1, p211
- ISSN
0305-7453
- Publication type
Article
- DOI
10.1093/jac/dkt340