Rotator cuff tendon assessment using magic-angle insensitive 3D ultrashort echo time cones magnetization transfer (UTE-Cones-MT) imaging and modeling with histological correlation.
- Authors
Zhu, Yanchun; Cheng, Xin; Ma, Yajun; Wong, Jonathan H.; Xie, Yaoqin; Du, Jiang; Chang, Eric Y.
- Abstract
<bold>Background: </bold>Rotator cuff tendons (RCTs) are challenging to image due to the "magic angle effect" and their short T2 .<bold>Purpose: </bold>To assess the degree of magic angle sensitivity of human RCTs and to utilize a 3D ultrashort echo time Cones sequence with magnetization transfer preparation (UTE-Cones-MT) and two-pool quantitative MT modeling with histological correlation. We hypothesized that MT parameters would be less sensitive to the magic angle compared with conventional T2 measurements.<bold>Study Type: </bold>Prospective imaging pathologic correlation.<bold>Specimen: </bold>Twenty cadaveric rotator cuff tendons were imaged at five sample orientations ranging from 0-90° relative to the B0 field.<bold>Field Strength/sequence: </bold>3T/3D UTE-Cones-MT and Carr-Purcell-Meiboom-Gill (CPMG).<bold>Assessment: </bold>Two-pool quantitative MT modeling parameters and T2 values were calculated in regions of interest drawn by a medical physicist. Histopathological analysis was performed and mild and severe tendinopathy groups were assigned by a histopathologist and histotechnician.<bold>Statistical Tests: </bold>Coefficients of variations (CVs) were calculated for measures between the different orientations and group means were compared for each measure.<bold>Results: </bold>CVs of T2 and macromolecular fractions between orientations were 26.14 ± 16.82% and 6.18 ± 2.77% (mean ± SD), respectively. T2 measurements at 0°, 27°, 70°, and 90° showed significant differences between the two histological groups (P = 0.004, 0.008, 0.003, and 0.015, respectively), but not at 55° (P = 0.611). Mean T2 value ranges between orientations for the mild and severe tendinopathy groups were 15.27-30.32 msec and 20.81-35.85 msec, respectively, showing overlap despite statistically significant differences (P = 0.003). Macromolecular fractions at all angles showed significant differences between the two groups (P < 0.0001). Mean fraction ranges between orientations for the mild and severe tendinopathy groups were 14.32-17.17% and 10.00-13.75% respectively (P < 0.0001) with no overlap.<bold>Data Conclusion: </bold>Compared with T2 , macromolecular fraction obtained with the 3D UTE-Cones-MT technique is resistant to the magic angle effect and is more sensitive to RCT degeneration.<bold>Level Of Evidence: </bold>1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2017.
- Publication
Journal of Magnetic Resonance Imaging, 2018, Vol 48, Issue 1, p160
- ISSN
1053-1807
- Publication type
journal article
- DOI
10.1002/jmri.25914