We found a match
Your institution may have rights to this item. Sign in to continue.
- Title
Effect of submucosal tunneling endoscopic resection for submucosal tumors at esophagogastric junction and risk factors for failure of en bloc resection.
- Authors
Li, Zhenjuan; Gao, Ying; Chai, Ningli; Xiong, Ying; Ma, Lianjun; Zhang, Wengang; Du, Chen; Linghu, Enqiang
- Abstract
<bold>Background and Aims: </bold>Most submucosal tumors (SMTs) in the esophagogastric junction (EGJ) are irregularly shaped and different from those in the esophagus, where submucosal tunneling endoscopic resection (STER) has been proven effective and safe. However, few reports paid attention to STER for SMTs in the EGJ. The aim of the study was not only to evaluate the effect of STER in patients with SMTs in the EGJ but to analyze the risk factors for failure of en bloc resection.<bold>Methods: </bold>A consecutive of 47 patients with SMTs originating from the muscularis propria (MP) layer in the EGJ underwent STER were retrospectively included between September 2012 and December 2016. Thirty-five tumors underwent en bloc resection, and the other 12 tumors received piecemeal resection. The tumor size, operation time, en bloc resection rate, complications, residual, and local recurrence were achieved and compared between the two groups.<bold>Results: </bold>Forty-six of 47 lesions (97.9%) were successfully resected. The mean lesion size was 29.7 ± 16.3 mm. Both the en bloc resection rate and complete resection rate were 74.5% (35/47). No severe complications occurred in the 47 patients. Patients in the piecemeal resection group had more irregularly shaped lesions, longer tumor diameter, larger tumor size (≥40 mm), longer operation time, and longer hospital stay after procedure (P < 0.05), and there were no statistically differences between the two groups in in-operative complications, post-operative complications, and residual rate (P > 0.05). By univariate analysis and stepwise logistic regression analysis, irregular shape and tumor diameter ≥20 mm were two risk factors for failure of en bloc resection.<bold>Conclusions: </bold>STER is an effective and safe technique for the treatment of SMTs arising from the MP layer in the EGJ. Irregular shape and tumor diameter ≥20 mm are the reliable risk factors for en bloc resection failure.
- Subjects
SUBMUCOUS plexus; ESOPHAGOGASTRIC junction; HOSPITAL care; UNIVARIATE analysis; LOGISTIC regression analysis; PHYSIOLOGY
- Publication
Surgical Endoscopy & Other Interventional Techniques, 2018, Vol 32, Issue 3, p1326
- ISSN
1866-6817
- Publication type
journal article
- DOI
10.1007/s00464-017-5810-8