Found: 21
Select item for more details and to access through your institution.
The preoperative Hounsfield unit value at the position of the future screw insertion is a better predictor of screw loosening than other methods.
- Published in:
- European Radiology, 2023, v. 33, n. 3, p. 1526, doi. 10.1007/s00330-022-09157-9
- By:
- Publication type:
- Article
Global research status and hot trends in stem cells therapy for Intervertebral disc degeneration: A bibliometric and clinical study analysis.
- Published in:
- Frontiers in Pharmacology, 2022, v. 10, p. 1, doi. 10.3389/fphar.2022.873177
- By:
- Publication type:
- Article
LncRNA HABON promoted liver cancer cells survival under hypoxia by inhibiting mPTP opening.
- Published in:
- Cell Death Discovery, 2022, v. 8, n. 1, p. 1, doi. 10.1038/s41420-022-00917-6
- By:
- Publication type:
- Article
Impact of screw tip design on screw anchorage: mechanical testing and numerical simulation.
- Published in:
- Journal of Orthopaedic Surgery & Research, 2024, v. 19, n. 1, p. 1, doi. 10.1186/s13018-024-04841-6
- By:
- Publication type:
- Article
Increasing the angle between caudal screw and the transverse plane may aggravate the risk of femoral head necrosis by deteriorating the fixation stability in patients with femoral neck fracture.
- Published in:
- European Journal of Medical Research, 2024, v. 29, n. 1, p. 1, doi. 10.1186/s40001-024-01737-3
- By:
- Publication type:
- Article
Biomechanical role of osteoporosis affects the incidence of adjacent segment disease after percutaneous transforaminal endoscopic discectomy.
- Published in:
- Journal of Orthopaedic Surgery & Research, 2019, v. 14, n. 1, p. N.PAG, doi. 10.1186/s13018-019-1166-1
- By:
- Publication type:
- Article
Changes in nail position and antirotation blade angles on the risk of femoral head varus in PFNA fixed patients: a clinical review and comprehensive biomechanical research.
- Published in:
- European Journal of Medical Research, 2024, v. 29, n. 1, p. 1, doi. 10.1186/s40001-024-01892-7
- By:
- Publication type:
- Article
Annulus Calibration Increases the Computational Accuracy of the Lumbar Finite Element Model.
- Published in:
- Global Spine Journal, 2023, v. 13, n. 8, p. 2310, doi. 10.1177/21925682221081224
- By:
- Publication type:
- Article
Reducing the extent of facetectomy may decrease morbidity in failed back surgery syndrome.
- Published in:
- 2019
- By:
- Publication type:
- journal article
Impact of blade direction on postoperative femoral head varus in PFNA fixed patients: a clinical review and biomechanical research.
- Published in:
- Frontiers in Bioengineering & Biotechnology, 2024, p. 1, doi. 10.3389/fbioe.2024.1381201
- By:
- Publication type:
- Article
Intervertebral-spreader-assisted anterior cervical discectomy and fusion prevents postoperative axial pain by alleviating facet joint pressure.
- Published in:
- Journal of Orthopaedic Surgery & Research, 2022, v. 17, n. 1, p. 1, doi. 10.1186/s13018-022-02983-z
- By:
- Publication type:
- Article
Disc measurement and nucleus calibration in a smoothened lumbar model increases the accuracy and efficiency of in-silico study.
- Published in:
- Journal of Orthopaedic Surgery & Research, 2021, v. 16, n. 1, p. 1, doi. 10.1186/s13018-021-02655-4
- By:
- Publication type:
- Article
Nucleus high intensity in the T2-weighted MRI is a potential predictor of annulus tear in cervical injured patients: a case comparative study.
- Published in:
- BMC Musculoskeletal Disorders, 2023, v. 24, n. 1, p. 1, doi. 10.1186/s12891-023-06615-3
- By:
- Publication type:
- Article
Indications Selection for Surgeons Training in the Translaminar Percutaneous Endoscopic Discectomy Based on Finite Element Analysis.
- Published in:
- BioMed Research International, 2020, p. 1, doi. 10.1155/2020/2960642
- By:
- Publication type:
- Article
Biomechanical Effects of Pedicle Screw Positioning on the Surgical Segment in Models After Oblique Lumbar Interbody Fusion: An in-silico Study.
- Published in:
- International Journal of General Medicine, 2022, v. 15, p. 1047, doi. 10.2147/IJGM.S352304
- By:
- Publication type:
- Article
TELD with limited foraminoplasty has potential biomechanical advantages over TELD with large annuloplasty: an in-silico study.
- Published in:
- 2021
- By:
- Publication type:
- journal article
Intraoperative capsule protection can reduce the potential risk of adjacent segment degeneration acceleration biomechanically: an in silico study.
- Published in:
- Journal of Orthopaedic Surgery & Research, 2024, v. 19, n. 1, p. 1, doi. 10.1186/s13018-024-04550-0
- By:
- Publication type:
- Article
Fixation-induced surgical segment's high stiffness and the damage of posterior structures together trigger a higher risk of adjacent segment disease in patients with lumbar interbody fusion operations.
- Published in:
- Journal of Orthopaedic Surgery & Research, 2023, v. 18, n. 1, p. 1, doi. 10.1186/s13018-023-03838-x
- By:
- Publication type:
- Article
Nerve abnormalities in lumbar disc herniation: A systematic review and meta-analysis of diffusion tensor imaging.
- Published in:
- PLoS ONE, 2022, v. 17, n. 12, p. 1, doi. 10.1371/journal.pone.0279499
- By:
- Publication type:
- Article
High-speed electro-optic modulation in topological interface states of a one-dimensional lattice.
- Published in:
- Light: Science & Applications, 2023, v. 12, n. 1, p. 1, doi. 10.1038/s41377-023-01251-x
- By:
- Publication type:
- Article
Preparation and Hardened Performance of Bentonite-Induced Porous Magnesium Oxysulfate Cement Paste.
- Published in:
- Materials (1996-1944), 2022, v. 15, n. 19, p. 6872, doi. 10.3390/ma15196872
- By:
- Publication type:
- Article