We found a match
Your institution may have rights to this item. Sign in to continue.
- Title
The Incidence of Adjacent Segment Degeneration after the Use of a Versatile Dynamic Hybrid Stabilization Device in Lumbar Stenosis: Results of a 5-8-Year Follow-up.
- Authors
Dobran, Mauro; Nasi, Davide; Esposito, Domenico Paolo; Gladi, Maurizio; Scerrati, Massimo; Iacoangeli, Maurizio
- Abstract
Study Design: Retrospective study with long-term follow-up. Purpose: To evaluate the long-term incidence of adjacent segment degeneration (ASD) and clinical outcomes in a consecutive series of patients who underwent spinal decompression associated with dynamic or hybrid stabilization with a Flex+TM stabilization system (SpineVision, Antony, France) for lumbar spinal stenosis. Overview of Literature: The incidence of ASD and clinical outcomes following dynamic or hybrid stabilization with the Flex+TM system used for lumbar spinal stenosis have not been well investigated. Methods: Twenty-one patients with lumbar stenosis and probable post-decompressive spinal instability underwent decompressive laminectomy followed by spinal stabilization using the Flex+TM stabilization system. The indication for a mono-level dynamic stabilization was a preoperative magnetic resonance imaging (MRI) demonstrating evidence of severe disc disease associated with severe spinal stenosis. The hybrid stabilization (rigid-dynamic) system was used for multilevel laminectomies with associated initial degenerative scoliosis, first-grade spondylolisthesis, or rostral pathology. Results: The improvement in Visual Analog Scale and Oswestry Disability Index scores at follow-up were statistically significant (p <0.0001 and p <0.0001, respectively). At the 5-8-year follow-up, clinical examination, MRI, and X-ray findings showed an ASD complication with pain and disability in one of 21 patients. The clinical outcomes were similar in patients treated with dynamic or hybrid fixation. Conclusions: Patients treated with laminectomy and Flex+TM stabilization presented a satisfactory clinical outcome after 5-8 years of follow-up, and ASD incidence in our series was 4.76% (one patient out of 21). We are aware that this is a small series, but our long-term follow-up may be sufficient to contribute to the expanding body of literature on the development of symptomatic ASD associated with dynamic or hybrid fixation.
- Subjects
SPINAL stenosis; SURGICAL decompression; SPINAL surgery; SPINE; VISUAL analog scale; MAGNETIC resonance imaging
- Publication
Asian Spine Journal, 2018, Vol 12, Issue 2, p263
- ISSN
1976-1902
- Publication type
Article
- DOI
10.4184/asj.2018.12.2.263