We found a match
Your institution may have rights to this item. Sign in to continue.
- Title
Targeting Diagnosis of High‐Risk Papillary Thyroid Carcinoma Using Ultrasound Contrast Agent With the BRAF<sup>V600E</sup> Mutation: An Experimental Study.
- Authors
Xie, Fang; Yan, Lin; Li, Yi‐Ming; Lan, Yu; Xiao, Jing; Zhang, Ming‐Bo; Jin, Zhuang; Zhang, Ying; Tian, Xiao‐Qi; Zhu, Ya‐Qiong; Li, Zhi‐Ping; Luo, Yu‐Kun
- Abstract
Objective: High‐risk papillary thyroid carcinoma (PTC) patients with BRAF mutation have lymph node and distant metastases and poor prognosis. Therefore, this study aims to develop a targeted ultrasound contrast agent for the BRAFV600E mutation to screen high‐risk PTC at early stage. Methods: The targeted lipid nanobubbles carrying BRAFV600E antibody were prepared using thin film hydration‐sonication and avidin‐biotin binding methods. The physicochemical properties and stability of the targeted nanobubbles were detected by transmission electron microscopy, atomic force microscopy, and confocal laser scanning microscopy. The target binding abilities of the targeted nanobubbles in the PTC cells (B‐CPAP) overexpressed mutant BRAFV600E were evaluated by immunofluorescence staining, quantitative real‐time polymerase chain reaction, western blot, and fluorescence microscopy. After PTC tumor models overexpressed mutant BRAFV600E were established, the enhanced images of targeted lipid nanobubbles and untargeted lipid nanobubbles on PTC tumors in nude mice were observed using contrast‐enhanced ultrasound imaging. Results: The targeted lipid nanobubbles revealed uniform, round morphology, and good stability with a nanoscale size. Besides, BRAFV600E monoclonal antibody was observed to be combined on the surface of lipid nanobubbles. Furthermore, the targeted nanobubbles had a good targeting diagnosis ability in PTC cells with BRAFV600E overexpression. Moreover, the targeted nanobubbles had better ultrasound enhancement and peak intensity of the time‐intensity curve (P <.001) in PTC tumors with BRAFV600E overexpression as compared to the untargeted lipid nanobubbles. Conclusion: The targeted lipid nanobubbles carrying BRAFV600E antibody could be regarded as a potential targeted ultrasound contrast agent for the diagnosis of high‐risk PTC. Access the CME test here and search by article title.
- Subjects
MICROBUBBLE diagnosis; ULTRASOUND contrast media; CONTRAST-enhanced ultrasound; PAPILLARY carcinoma; THYROID cancer; ATOMIC force microscopy; DIAGNOSIS
- Publication
Journal of Ultrasound in Medicine, 2022, Vol 41, Issue 11, p2789
- ISSN
0278-4297
- Publication type
Article
- DOI
10.1002/jum.15967