Editorial for "Quiescent‐Interval Slice‐Selective (QISS) MRI Accurately Estimates Intravascular Stent Dimensions Prior to Intervention in Patients with Peripheral Artery Disease".
- Authors
Zhong, Liang; Chong, Tze Tec
- Abstract
The preprocedural stent size measured from QISS was compared to CTA using the physical stent size as the reference standard. Editorial for "Quiescent-Interval Slice-Selective (QISS) MRI Accurately Estimates Intravascular Stent Dimensions Prior to Intervention in Patients with Peripheral Artery Disease" Endovascular interventions for peripheral artery disease (PAD) have long overtaken surgical bypass as the preferred option for many patients.1 Its lower morbidity and mortality coupled with advances in technology now show good long-term results post intervention.2 Revascularization centers around balloon angioplasty and stenting.
- Subjects
INTRAVASCULAR ultrasonography; PERIPHERAL vascular diseases; MAGNETIC resonance imaging; MAGNETIC resonance angiography; DIGITAL subtraction angiography; TRANSLUMINAL angioplasty
- Publication
Journal of Magnetic Resonance Imaging, 2022, Vol 55, Issue 6, p1810
- ISSN
1053-1807
- Publication type
Editorial
- DOI
10.1002/jmri.27886