Comparative Assessment of Digital Pathology Systems for Primary Diagnosis.
- Authors
Rajaganesan, Sathyanarayanan; Kumar, Rajiv; Rao, Vidya; Pai, Trupti; Mittal, Neha; Sahay, Ayushi; Menon, Santosh; Desai, Sangeeta
- Abstract
Background: Despite increasing interest in whole-slide imaging (WSI) over optical microscopy (OM), limited information on comparative assessment of various digital pathology systems (DPSs) is available. Materials and Methods: A comprehensive evaluation was undertaken to investigate the technical performance-assessment and diagnostic accuracy of four DPSs with an objective to establish the noninferiority of WSI over OM and find out the best possible DPS for clinical workflow. Results: A total of 2376 digital images, 15,775 image reads (OM - 3171 + WSI - 12,404), and 6100 diagnostic reads (OM - 1245, WSI - 4855) were generated across four DPSs (coded as DPS: 1, 2, 3, and 4) using a total 240 cases (604 slides). Onsite technical evaluation revealed successful scan rate: DPS3 < DPS2 < DPS4 < DPS1; mean scanning time: DPS4 < DPS1 < DPS2 < DPS3; and average storage space: DPS3 < DPS2 < DPS1 < DPS4. Overall diagnostic accuracy, when compared with the reference standard for OM and WSI, was 95.44% (including 2.48% minor and 2.08% major discordances) and 93.32% (including 4.28% minor and 2.4% major discordances), respectively. The difference between the clinically significant discordances by WSI versus OM was 0.32%. Major discordances were observed mostly using DPS4 and least in DPS1; however, the difference was statistically insignificant. Almost perfect (κ = 0.8)/substantial (κ = 0.6-0.8) inter/intra-observer agreement between WSI and OM was observed for all specimen types, except cytology. Overall image quality was best for DPS1 followed by DPS4. Mean digital artifact rate was 6.8% (163/2376 digital images) and maximum artifacts were noted in DPS2 (n = 77) followed by DPS3 (n = 36). Most pathologists preferred viewing software of DPS1 and DPS2. Conclusion: WSI was noninferior to OM for all specimen types, except for cytology. Each DPS has its own pros and cons; however, DPS1 closely emulated the real-world clinical environment. This evaluation is intended to provide a roadmap to pathologists for the selection of the appropriate DPSs while adopting WSI.
- Subjects
DIGITAL images; PATHOLOGY; MICROSCOPY; PATHOLOGISTS; CYTOLOGY
- Publication
Journal of Pathology Informatics, 2021, Vol 12, p1
- ISSN
2229-5089
- Publication type
Article
- DOI
10.4103/jpi.jpi_94_20