We found a match
Your institution may have rights to this item. Sign in to continue.
- Title
Comparison of the radial and brachial artery flow-mediated dilation in patients with hypertension.
- Authors
Majka, Katarzyna; Parol, Marzena; Nowicki, Andrzej; Gambin, Barbara; Trawiński, Zbigniew; Jaciubek, Marzena; Krupienicz, Andrzej; Olszewski, Robert
- Abstract
Background. Blood flow-mediated dilation (FMD) is a noninvasive assessment of vascular endothelial function in humans. The study of the FMD in hypertensive (HT) patients is an important factor supporting the recognition of the early mechanisms of cardiovascular pathologies, and also of the pathogenesis related to hypertension. Objectives. To investigate whether FMD measured on the radial artery (FMD-RA) using high-frequency ultrasounds can be used as an alternative to FMD assessed with the lower frequency system on the brachial artery in patients with HT. Materials and methods. The simultaneous measurements of FMD-RA and FMD measurements in the brachial artery (FMD-BA) were performed on 76 HT patients using 20 MHz and 7-12 MHz linear array probes, and were compared to the FMD measured in healthy groups. All quantitative data are presented as mean ± standard deviation (SD); the p-values of the normality and tests for variables comparisons are listed. The agreement of the FMD-RA and FMD-BA in HT patients was assessed with the Bland-Altman method, and using the intraclass correlation coefficient (ICC). In some statistical calculations, the FMD-RA values were rescaled by dividing them by a factor of 2. Results. The mean FMD-RA and FMD-BA in HT patients were 5.16 ±2.18% (95% confidence interval (95% CI): [4.50%, 5.82%]) and 2.13 ±1.12% (95% CI: [1.76%, 2.49%]), respectively. The FMD-RA and FMDBA values of HT patients were significantly different than those in respective control groups. The p-values of Mann-Whitney-Wilcoxon tests were less than 0.05. The Bland-Altman coefficient for both measurement methods, FMD-RA and FMD-BA, was 3%, and the ICC was 0.69. Conclusions. Our findings show that FMD-RA, supplementary to FMD-BA measurements, can be used to assess endothelial dysfunction in the group of HT patients. In addition, the FMD-RA measurements met the criteria of high concordance with the FMD-BA measurements.
- Subjects
BRACHIAL artery; RADIAL artery; HYPERTENSION; INTRACLASS correlation; ENDOTHELIUM diseases
- Publication
Advances in Clinical & Experimental Medicine, 2022, Vol 31, Issue 3, p241
- ISSN
1899-5276
- Publication type
Article
- DOI
10.17219/acem/144040