We found a match
Your institution may have rights to this item. Sign in to continue.
- Title
Positive Impact of [18F]FDG-PET/CT on Mortality in Patients With Staphylococcus aureus Bacteremia Explained by Immortal Time Bias.
- Authors
Vaart, Thomas W van der; Prins, Jan M; Werkhoven, Cornelis H van; Doesschate, Thijs ten; Soetekouw, Robin; Twillert, Gitte van; Veenstra, Jan; Herpers, Bjorn L; Rozemeijer, Wouter; Jansen, Rogier R; Bonten, Marc J M; Meer, Jan T M van der
- Abstract
Background Several studies have suggested that in patients with Staphylococcus aureus bacteremia (SAB) [18F] fluorodeoxyglucose positron emission tomography/computed tomography ([18F]FDG-PET/CT) improves outcome. However, these studies often ignored possible immortal time bias. Methods Prospective multicenter cohort study in 2 university and 5 non-university hospitals, including all patients with SAB. [18F]FDG-PET/CT was performed on clinical indication as part of usual care. Primary outcome was 90-day all-cause mortality. Effect of [18F]FDG-PET/CT was modeled with a Cox proportional hazards model using [18F]FDG-PET/CT as a time-varying variable and corrected for confounders for mortality (age, Charlson score, positive follow-up cultures, septic shock, and endocarditis). Secondary outcome was 90-day infection-related mortality (assessed by adjudication committee) using the same analysis. In a subgroup-analysis, we determined the effect of [18F]FDG-PET/CT in patients with high risk of metastatic infection. Results Of 476 patients, 178 (37%) underwent [18F]FDG-PET/CT. Day-90 all-cause mortality was 31% (147 patients), and infection-related mortality was 17% (83 patients). The confounder adjusted hazard ratio (aHR) for all-cause mortality was 0.50 (95% confidence interval [CI]:.34–.74) in patients that underwent [18F]FDG-PET/CT. Adjustment for immortal time bias changed the aHR to 1.00 (95% CI.68–1.48). Likewise, after correction for immortal time bias, [18F]FDG-PET/CT had no effect on infection-related mortality (cause specific aHR 1.30 [95% CI.77–2.21]), on all-cause mortality in patients with high-risk SAB (aHR 1.07 (95% CI.63–1.83) or on infection-related mortality in high-risk SAB (aHR for 1.24 [95% CI.67–2.28]). Conclusions After adjustment for immortal time bias [18F]FDG-PET/CT was not associated with day-90 all-cause or infection-related mortality in patients with SAB.
- Subjects
BACTEREMIA; RESEARCH; CAUSES of death; CONFIDENCE intervals; TIME; POSITRON emission tomography computed tomography; STAPHYLOCOCCAL diseases; TREATMENT effectiveness; RADIOPHARMACEUTICALS; POSITRON emission tomography; STAPHYLOCOCCUS aureus; UNIVERSITIES &; colleges; DESCRIPTIVE statistics; DEOXY sugars; COMPUTED tomography; DATA analysis software; LONGITUDINAL method; PROPORTIONAL hazards models; DISEASE complications
- Publication
Clinical Infectious Diseases, 2023, Vol 77, Issue 1, p9
- ISSN
1058-4838
- Publication type
Article
- DOI
10.1093/cid/ciad112