We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Parametric Sensitivity of Municipal Solid Waste Integrated Power Plant: CO<sub>2</sub> Footprint and Energy Analysis.
- Authors
Khan, Ashim Kumar; Chowdhury, Ranjana
- Abstract
The performance of an integrated gasification combined cycle based power plant using a mixture of municipal solid waste (MSW) and coal was evaluated. The parametric sensitivities of avoidance in CO2 emission (ACE) and the energy return on energy investment (EROEI) were analyzed by MSW‐coal ratio, gasifier temperature, and the air supplied for gasification as the independent variables. The data on ACE and EROEI simulated by Aspen Plus at different combinations of input parameters, pre‐set using the Box‐Behnken type design of experiments, were employed. Through response surface methodology, a valid model demonstrating the strong influence of MSW‐coal ratio and gasifier temperature on both the ACE and EROEI was developed.
- Subjects
COMBINED cycle power plants; COAL gasification plants; INTEGRATED gasification combined cycle power plants; SOLID waste; RESPONSE surfaces (Statistics); POWER plants
- Publication
Chemical Engineering & Technology, 2021, Vol 44, Issue 2, p291
- ISSN
0930-7516
- Publication type
Article