- Title
Continuous Glucose Monitoring to Diagnose Hypoglycemia Due to Late Dumping Syndrome in Children After Gastric Surgeries.
- Authors
Chesser, Hannah; Abdulhussein, Fatema; Huang, Alyssa; Lee, Janet Y; Gitelman, Stephen E
- Abstract
Gastrostomy tubes (G-tubes) and Nissen fundoplication are common surgical interventions for feeding difficulties and gastroesophageal reflux disease in children. A potential yet often missed, complication of these procedures is dumping syndrome. We present 3 pediatric patients with postprandial hypoglycemia due to late dumping syndrome after gastric surgeries. All patients received gastrostomy tubes for feeding intolerance: 2 had Nissen fundoplication for gastroesophageal reflux disease, and 1 had tracheoesophageal repair. All patients underwent multiple imaging studies in an to attempt to diagnose dumping syndrome. Continuous glucose monitoring (CGM) was essential for detecting asymptomatic hypoglycemia and glycemic excursions occurring with feeds that would have gone undetected with point-of-care (POC) blood glucose checks. CGM was also used to monitor the effectiveness of treatment strategies and drive treatment plans. These cases highlight the utility of CGM in diagnosing postprandial hypoglycemia due to late dumping syndrome, which is infrequently diagnosed by imaging studies and intermittent POC blood glucose measurements.
- Subjects
BLOOD sugar monitoring; HYPOGLYCEMIA in children; DUMPING syndrome
- Publication
Journal of the Endocrine Society, 2021, Vol 5, Issue 3, p1
- ISSN
2472-1972
- Publication type
Article
- DOI
10.1210/jendso/bvaa197