We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Heißbemessung unter Berücksichtigung der Feuerverzinkung: Brandschutz R30 im Cruise Center Baakenhöft.
- Authors
Pinger, Thomas; Schienbein, Frank; Sothmann, Jörg
- Abstract
Structural fire design utilizing hot‐dip galvanizing – fire protection R30 at Cruise Center Baakenhöft Current research results have shown that hot‐dip galvanizing of steel structures can achieve a more favorable behavior under fire conditions in terms of slower heating of galvanized steel members. If corrosion protection and/or mechanical resistance of steel surfaces is also required, the various requirements can be met utilizing hot‐dip galvanizing and thus provide an economically attractive solution without the need of additional passive fire protection measures. At the newly built Cruise Center Baakenhöft in HafenCity Hamburg, these findings have now been implemented for the first time; this article covers the relevant underlying considerations, procedures for structural fire design and execution on site.
- Subjects
GALVANIZING; GALVANIZED steel; FIRE prevention; STRUCTURAL design; CORROSION &; anti-corrosives; FIRE testing
- Publication
Bautechnik, 2020, Vol 97, Issue 8, p575
- ISSN
0932-8351
- Publication type
Article
- DOI
10.1002/bate.202000050