We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Comparison of intraoperative anthropometric measurements of the proximal tibia and tibial component in total knee arthroplasty.
- Authors
Miyatake, Naohisa; Sugita, Takehiko; Aizawa, Toshimi; Sasaki, Akira; Maeda, Ikuo; Kamimura, Masayuki; Fujisawa, Hirokazu; Takahashi, Atsushi
- Abstract
<bold>Background: </bold>Precise matching of the tibial component and resected bony surfaces and proper rotational implanting of the tibial component are crucial for successful total knee arthroplasty. We aimed to analyze the exact anthropometric proximal tibial data of Japanese patients undergoing total knee arthroplasty and correlate the measurements with the dimensions of current total knee arthroplasty systems.<bold>Methods: </bold>A total of 703 knees in 566 Japanese patients who underwent total knee arthroplasty for osteoarthritis were included. The bone resection in the proximal tibia was performed perpendicular to the tibial axis in the frontal plane. Measurements of the proximal tibia were intraoperatively obtained after proximal tibial preparation.<bold>Results: </bold>There were significant positive correlations between the lateral anteroposterior and medial anteroposterior and mediolateral dimensions. A progressive decrease in the mediolateral/lateral anteroposterior ratio with an increasing lateral anteroposterior dimension or the mediolateral/anteroposterior ratio with an increasing anteroposterior dimension was observed. The lateral anteroposterior dimension was smaller than the medial anteroposterior dimension by a mean of 4.8 ± 2.0 mm. The proximal tibia exhibited asymmetry between the lateral and medial plateaus. A comparison of the morphological data and dimensions of the implants, one of which was a symmetric tibial component (NexGen) and the others were asymmetric (Genesis II and Persona), indicated that an asymmetric tibial component could be beneficial to maximize tibial plateau coverage.<bold>Conclusions: </bold>This study provided important reference data for designing a proper tibial component for Japanese people. The proximal tibial cut surface was asymmetric. There was wide dispersion in the lateral anteroposterior, medial anteroposterior, and mediolateral dimensions depending on the patient. Our data showed that the tibial components of the Genesis II and Persona rather than that of the NexGen may be preferable for Japanese people because of their asymmetric design.
- Subjects
JAPAN; ANTHROPOMETRY; TIBIA; TOTAL knee replacement; OSTEOARTHRITIS; INTRAOPERATIVE care; COMPARISON (Rhetoric); AGE distribution; ARTIFICIAL joints; INTRAOPERATIVE monitoring; KNEE diseases; LONGITUDINAL method; RISK assessment; SEX distribution; TREATMENT effectiveness; RETROSPECTIVE studies; ANATOMY
- Publication
Journal of Orthopaedic Science, 2016, Vol 21, Issue 5, p635
- ISSN
0949-2658
- Publication type
journal article
- DOI
10.1016/j.jos.2016.06.003