We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Chronological Changes of C-Reactive Protein Levels Following Uncomplicated, Two-Staged, Bilateral Deep Brain Stimulation.
- Authors
Jae-hun Kim; Sang-woo Ha; Jin-gyu Choi; Byung-chul Son
- Abstract
Objective: The occurrence of acute cerebral infection following deep brain stimulation (DBS) is currently being reported with elevation of C-reactive protein (CRP) level. The aim of the present study was to establish normal range of the magnitude and time-course of CRP increases following routine DBS procedures in the absence of clinical and laboratory signs of infection. Methods: A retrospective evaluation of serial changes of plasma CRP levels in 46 patients undergoing bilateral, two-staged DBS was performed. Because DBS was performed as a two-staged procedure involving; implantation of lead and internal pulse generator (IPG), CRP was measured preoperatively and postoperatively every 2 days until normalization of CRP (post-lead implantation day 2 and 4, post-IPG implantation day 2, 4, and 6). Results: Compared with preoperative CRP levels (0.12±0.17 mg/dL, n=46), mean CRP levels were significantly elevated after lead insertion day 2 and 4 (1.68±1.83 mg/dL, n=46 and 0.76±0.38 mg/dL, n=16, respectively, p<0.001). The mean CRP levels at post-lead implantation day 2 were further elevated at post-IPG implantation day 2 (3.41±2.56 mg/dL, n=46, respectively, p<0.01). This elevation in post-IPG day 2 rapidly declined in day 4 (1.24±1.29 mg/dL, n=46, p<0.05) and normalized to preoperative value at day 6 (0.42±0.33 mg/dL, n=46, p>0.05). Mean CRP levels after IPG implantation were significantly higher in patients whose IPGs were implanted at post-lead day 3 than those at post-lead day 5-6 (3.99±2.80 mg/dL, n=30, and 2.31±1.56 mg/dL, n=16, respectively, p<0.05). However, there was no difference in post-IPG day 2 and 4 between them (p>0.05). Conclusion: The mean postoperative CRP levels were highest on post-IPG insertion day 2 and decreased rapidly, returning to the normal range on post-IPG implantation day 6. The duration of post-lead implantation period influenced the magnitude of CRP elevation at post-IPG insertion day 2. Information about the normal response of CRP following DBS could help to avoid unnecessary diagnostic and therapeutic efforts.
- Subjects
C-reactive protein; DEEP brain stimulation; BRAIN disease research; ENCEPHALITIS; INFLAMMATION
- Publication
Journal of Korean Neurosurgical Society, 2015, Vol 58, Issue 4, p368
- ISSN
2005-3711
- Publication type
Article
- DOI
10.3340/jkns.2015.58.4.368