We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Air embolism through open hub of external jugular vein intravenous cannula.
- Authors
Mohanty, Chitta R.; Ahmad, Suma R.; Jain, Mantu; Sriramka, Bhavna
- Abstract
Introduction: Venous air embolism is a catastrophic complication that can result in sudden cardiac arrest and death. Massive air embolism has been reported with central venous catheter through the internal jugular and subclavian veins. Though external jugular vein is a potential site of an air embolism to cardiac chambers and subsequently to vital organs such as brain, heart and lungs but has not been reported yet in literature. Case presentation: We are reporting a case of sudden pulmonary air embolism in a patient through the open hub of an intravenous cannula, vigilant monitoring and timely action saved the patient from a catastrophic outcome. Conclusion: We recommend vigilant monitoring and adequate precaution in patients with external jugular venous cannulation in the operation theater, intensive care unit or wards to prevent iatrogenic complications.
- Subjects
GAS embolism; JUGULAR vein; CATHETERS; CENTRAL venous catheters; CARDIAC arrest
- Publication
Turkish Journal of Emergency Medicine, 2020, Vol 20, Issue 3, p117
- ISSN
1304-7361
- Publication type
Article
- DOI
10.1016/j.tjem.2019.06.002