The corrosion of steel-structured platform canopies of domestic high-speed rail stations in service was investigated. The failure of the protective coatings on the steel structures of platform canopies with different structural styles was summarized. The causes for the failure of coatings were analyzed. Several issues needing further study about protection and repair were discussed. Some available solutions with respect to prevention and maintenance were provided.