We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Sensitivity of <sup>18</sup>F-fluorodihydrotestosterone PET-CT to count statistics and reconstruction protocol in metastatic castration-resistant prostate cancer.
- Authors
Cysouw, Matthijs C. F.; Kramer, Gerbrand M.; Heijtel, Dennis; Schuit, Robert C.; Morris, Michael J.; van den Eertwegh, Alfons J. M.; Voortman, Jens; Hoekstra, Otto S.; Oprea-Lager, Daniela E.; Boellaard, Ronald
- Abstract
Objectives: Whole body [18F]-fluorodihydrotestosterone positron emission tomography ([18F]FDHT PET) imaging directly targets the androgen receptor and is a promising prognostic and predictive biomarker in metastatic castration-resistant cancer (mCRPC). To optimize [18F]FDHT PET-CT for diagnostic and response assessment purposes, we assessed how count statistics and reconstruction protocol affect its accuracy, repeatability, and lesion detectability. Methods: Whole body [18F]FDHT PET-CT scans were acquired on an analogue PET-CT on two consecutive days in 14 mCRPC patients harbouring a total of 336 FDHT-avid lesions. Images were acquired at 45 min post-injection of 200 MBq [18F]FDHT at 3 min per bed position. List-mode PET data were split on a count-wise basis, yielding two statistically independent scans with each 50% of counts. Images were reconstructed according to current EANM Research Ltd. (EARL1, 4 mm voxel) and novel EARL2 guidelines (4 mm voxel + PSF). Per lesion, we measured SUVpeak, SUVmax, SUVmean, and contrast-to-noise ratio (CNR). SUV was normalized to dose per bodyweight as well as to the parent plasma input curve integral. Variability was assessed with repeatability coefficients (RCs). Results: Count reduction increased liver coefficient of variation from 9.0 to 12.5% and from 10.8 to 13.2% for EARL1 and EARL2, respectively. SUVs of EARL2 images were 12.0–21.7% higher than EARL1. SUVs of 100% and 50% count data were highly correlated (R2 > 0.98; slope = 0.97–1.01; ICC = 0.99–1.00). Intrascan variability was volume-dependent, and count reduction resulted in higher intrascan variability for EARL2 than EARL1 images. Intrascan RCs were lowest for SUVmean (8.5–10.6%), intermediate for SUVpeak (12.0–16.0%), and highest for SUVmax (17.8–22.2%). Count reduction increased test-retest variance non-significantly (p > 0.05) for all SUV types and normalizations. For SUVpeak at 50% of counts, RCs remained < 30% when small lesions were excluded. Splitting data reduced CNR by median 4.6% (interquartile range 1.2–8.7%) and 4.6% (interquartile range 1.2–8.7%) for EARL1 and EARL2 images, respectively. Conclusions: Reducing [18F]FDHT PET acquisition time from 3 min to 1.5 per bed position resulted in a repeatability of SUVpeak (bodyweight) remaining ≤ 30%, which is generally acceptable for response monitoring purposes. However, EARL2 reconstruction was more affected, especially for SUVmax whose repeatability tended to exceed 30%. Lesion detectability was only slightly impaired by reducing acquisition time, which might not be clinically relevant in mCRPC.
- Subjects
POSITRON emission tomography computed tomography; CASTRATION-resistant prostate cancer; RESPONSE surfaces (Statistics); ANDROGEN receptors; STATISTICS
- Publication
EJNMMI Research, 2019, Vol 9, Issue 1, pN.PAG
- ISSN
2191-219X
- Publication type
Article
- DOI
10.1186/s13550-019-0531-8