We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Virtual non-contrast dual-energy CT compared to single-energy CT of the urinary tract: a prospective study.
- Authors
Lundin M; Lidén M; Magnuson A; Mohammed AA; Geijer H; Andersson T; Persson A; Lundin, Margareta; Lidén, Mats; Magnuson, Anders; Mohammed, Ahmed Abdulilah; Geijer, Håkan; Andersson, Torbjörn; Persson, Anders
- Abstract
<bold>Background: </bold>Dual-energy computed tomography (DECT) has been shown to be useful for subtracting bone or calcium in CT angiography and gives an opportunity to produce a virtual non-contrast-enhanced (VNC) image from a series where contrast agents have been given intravenously. High noise levels and low resolution have previously limited the diagnostic value of the VNC images created with the first generation of DECT. With the recent introduction of a second generation of DECT, there is a possibility of obtaining VNC images with better image quality at hopefully lower radiation dose compared to the previous generation. <bold>Purpose: </bold>To compare the image quality of the single-energy series to a VNC series obtained with a two generations of DECT scanners. CT of the urinary tract was used as a model. <bold>Material and Methods: </bold>Thirty patients referred for evaluation of hematuria were examined with an older system (Somatom Definition) and another 30 patients with a new generation (Somatom Definition Flash). One single-energy series was obtained before and one dual-energy series after administration of intravenous contrast media. We created a VNC series from the contrast-enhanced images. Images were assessed concerning image quality with a visual grading scale evaluation of the VNC series with the single-energy series as gold standard. <bold>Results: </bold>The image quality of the VNC images was rated inferior to the single-energy variant for both scanners, OR 11.5-67.3 for the Definition and OR 2.1-2.8 for the Definition Flash. Visual noise and overall quality were regarded as better with Flash than Definition. <bold>Conclusion: </bold>Image quality of VNC images obtained with the new generation of DECT is still slightly inferior compared to native images. However, the difference is smaller with the new compared to the older system.
- Subjects
IMAGE quality in imaging systems; COMPUTED tomography; ANGIOGRAPHY; URINARY organ examination; HEMATURIA
- Publication
Acta Radiologica, 2012, Vol 53, Issue 6, p689
- ISSN
0284-1851
- Publication type
journal article
- DOI
10.1258/ar.2012.110661