We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Sensitivity Assessment of Rapid Influenza Diagnostic Tests for the Detection of the 2009 Pandemic Influenza A (H1N1) Virus in Clinical Specimens.
- Authors
Chen Ming; Xiao Wei; Ai Biao; He Han; Liu Xuezheng; Dong Hong; Xiong Jun; Xu Li
- Abstract
Background: Influenza antigen detection test kits can provide results in 30 minutes and are used frequently for the detection of seasonal influenza infections. It is very important to determine the efficacy of these tests in the diagnosis of the 2009 pandemic influenza A (H1N1) virus due to the global spread of this new influenza virus. Methods: We evaluated 4 rapid influenza diagnostic tests (Binax Now Influenza A&B, BD Directigen EZ Flu A+B, Fujirebio Espline Influenza A&B-N, and BioTracer Influenza A&B Test) for their ability to detect the 2009 pandemic influenza A (H1N1) virus and compared these results with the diagnostic sensitivity obtained following real-time polymerase chain reaction (PCR) analysis of the same samples. Results: Reverse transcriptase polymerase chain reaction (RT-PCR) analysis of 252 specimens identified 176 influenza A (H1N1) positive samples. Of these, between 29 and 62 also tested positive using the 4 rapid tests examined, demonstrating the sensitivity of the respective tests was 16.5%-35.2% with specificities of 100%. However, the 4 rapid tests were 77.3%-100% sensitive when samples contained high influenza A (H1N1) virus titers, suggesting the sensitivity of these detection kits was dependent on viral loads. Finally, the sensitivity of the 4 detection kits tested was higher when samples from children were examined compared with samples from adults. Conclusions: Data presented in this report indicated the sensitivity of the respective influenza antigen detection test kits examined was low compared to the sensitivity observed following RT-PCR. Nonetheless, they are useful tools during early outbreak investigations of influenza-like illnesses, particularly in the screening of critically ill patients and pediatric patients. However, negative results could be confirmed using other tests (eg, RT-PCR if necessary).
- Subjects
H1N1 influenza; DIAGNOSTIC reagents &; test kits; POLYMERASE chain reaction; RESEARCH funding; INDUSTRIAL research; VIRAL load; PREDICTIVE tests; REVERSE transcriptase polymerase chain reaction; DATA analysis software; DIAGNOSIS
- Publication
Laboratory Medicine, 2010, Vol 41, Issue 12, p731
- ISSN
0007-5027
- Publication type
Article
- DOI
10.1309/LM1SH48AEBLVMJUQ