We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Kinematically aligned total knee arthroplasty limits high tibial forces, differences in tibial forces between compartments, and abnormal tibial contact kinematics during passive flexion.
- Authors
Roth, Joshua D.; Howell, Stephen M.; Hull, Maury L.
- Abstract
<bold>Purpose: </bold>Following total knee arthroplasty (TKA), high tibial forces, large differences in tibial forces between the medial and lateral compartments, and anterior translation of the contact locations of the femoral component on the tibial component during passive flexion indicate abnormal knee function. Because the goal of kinematically aligned TKA is to restore native knee function without soft tissue release, the objectives were to determine how well kinematically aligned TKA limits high tibial forces, differences in tibial forces between compartments, and anterior translation of the contact locations of the femoral component on the tibial component during passive flexion.<bold>Methods: </bold>Using cruciate retaining components, kinematically aligned TKA was performed on thirteen human cadaveric knee specimens with use of manual instruments without soft tissue release. The tibial forces and tibial contact locations were measured in both the medial and lateral compartments from 0° to 120° of passive flexion using a custom tibial force sensor.<bold>Results: </bold>The average total tibial force (i.e. sum of medial + lateral) ranged from 5 to 116 N. The only significant average differences in tibial force between compartments occurred at 0° of flexion (29 N, p = 0.0008). The contact locations in both compartments translated posteriorly in all thirteen kinematically aligned TKAs by an average of 14 mm (p < 0.0001) and 18 mm (p < 0.0001) in the medial and lateral compartments, respectively, from 0° to 120° of flexion.<bold>Conclusions: </bold>After kinematically aligned TKA, average total tibial forces due to the soft tissue restraints were limited to 116 N, average differences in tibial forces between compartments were limited to 29 N, and a net posterior translation of the tibial contact locations was observed in all kinematically aligned TKAs during passive flexion from 0° to 120°, which are similar to what has been measured previously in native knees. While confirmation in vivo is warranted, these findings give surgeons who perform kinematically aligned TKA confidence that the alignment method and surgical technique limit high tibial forces, differences in tibial forces between compartments, and anterior translation of the tibial contact locations during passive flexion.
- Subjects
TOTAL knee replacement; KNEE pain; KNEE surgery; PATIENT satisfaction; OSTEOARTHRITIS diagnosis; TIBIA surgery; ARTIFICIAL joints; BONE diseases; DEAD; RANGE of motion of joints; KINEMATICS; KNEE; TIBIA; PREVENTION
- Publication
Knee Surgery, Sports Traumatology, Arthroscopy, 2018, Vol 26, Issue 6, p1589
- ISSN
0942-2056
- Publication type
journal article
- DOI
10.1007/s00167-017-4670-z