Evaluation of the Oxycon Mobile metabolic system against the Douglas bag method.
- Authors
Rosdahl, Hans; Gullstrand, Lennart; Salier-Eriksson, Jane; Johansson, Patrik; Schantz, Peter
- Abstract
The aim of this study was to evaluate two versions of the Oxycon Mobile portable metabolic system (OMPS1 and OMPS2) in a wide range of oxygen uptake, using the Douglas bag method (DBM) as criterion method. The metabolic variables $$ \dot{V}{\text{O}}_{2} , \dot{V}{\text{CO}}_{2} , $$ respiratory exchange ratio and $$ \dot{V}_{\text{E}} $$ were measured during submaximal and maximal cycle ergometer exercise with sedentary, moderately trained individuals and athletes as participants. Test–retest reliability was investigated using the OMPS1. The coefficients of variation varied between 2 and 7% for the metabolic parameters measured at different work rates and resembled those obtained with the DBM. With the OMPS1, systematic errors were found in the determination of $$ \dot{V}{\text{O}}_{2} $$ and $$ \dot{V}{\text{CO}}_{2} . $$ At submaximal work rates $$ \dot{V}{\text{O}}_{2} $$ was 6–14% and $$ \dot{V}{\text{CO}}_{2} $$ 5–9% higher than with the DBM. At $$ \dot{V}{\text{O}}_{2\max } $$ both $$ \dot{V}{\text{O}}_{2} $$ and $$ \dot{V}{\text{CO}}_{2} $$ were slightly lower as compared to DBM (−4.1 and −2.8% respectively). With OMPS2, $$ \dot{V}{\text{O}}_{2} $$ was determined accurately within a wide measurement range (about 1–5.5 L min−1), while $$ \dot{V}{\text{CO}}_{2} $$ was overestimated (3–7%). $$ \dot{V}_{\text{E}} $$ was accurate at submaximal work rates with both OMPS1 and OMPS2, whereas underestimations (4–8%) were noted at $$ \dot{V}{\text{O}}_{2\max } .$$ The present study is the first to demonstrate that a wide range of $$ \dot{V}{\text{O}}_{2} $$ can be measured accurately with the Oxycon Mobile portable metabolic system (second generation). Future investigations are suggested to clarify reasons for the small errors noted for $$ \dot{V}_{\text{E}} $$ and $$ \dot{V}{\text{CO}}_{2} $$ versus the Douglas bag measurements, and also to gain knowledge of the performance of the device under applied and non-laboratory conditions.
- Subjects
DYNAMOMETER; PHYSICAL fitness; METHODOLOGY; SPORTS personnel; SCOUTING (Athletics); ATHLETES; COMPARATIVE studies; RESEARCH methodology; MEDICAL cooperation; PATIENT monitoring; RESEARCH; RESEARCH evaluation; EVALUATION research; OXYGEN consumption
- Publication
European Journal of Applied Physiology, 2010, Vol 109, Issue 2, p159
- ISSN
1439-6319
- Publication type
journal article
- DOI
10.1007/s00421-009-1326-9