We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Real-Time Effects of Disconnection of the Ventilator on Regional Lung Volumes and Ventilation Distribution.
- Authors
Minaříková, Petronela; Batista Borges, João; Duška, František; Zvoníček, Václav
- Abstract
The article discusses research which evaluated real-time physiological effects of clamping the endotracheal tube (ETT) during mechanical ventilator disconnection on regional lung volumes and ventilation distribution. The study recorded pulmonary electric impedance tomography measurements of regional lung volumes and ventilation distribution with and without clamping. It analyzed intrapulmonary shunts using simultaneous arterial and central venous gas sampling.
- Subjects
BLOOD gases analysis; POSITIVE end-expiratory pressure; PULMONARY circulation; T-test (Statistics); TOMOGRAPHY; STATISTICAL sampling; RESPIRATORY insufficiency; ENDOTRACHEAL tubes; MEDICAL device removal; SURGICAL therapeutics; BIOELECTRIC impedance; RANDOMIZED controlled trials; DESCRIPTIVE statistics; INTUBATION; LONGITUDINAL method; CROSSOVER trials; LUNG volume measurements; COMPARATIVE studies; DATA analysis software; HEMORRHAGIC shock; MECHANICAL ventilators
- Publication
Respiratory Care, 2024, Vol 69, Issue 5, p608
- ISSN
0020-1324
- Publication type
Article
- DOI
10.4187/respcare.11550