We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) knee MRI at 3.0 T in the evaluation of the anterior cruciate ligament injury with additional views: comparison with two-dimensional fast spin-echo T2-weighted sequences.
- Authors
Park, Hee Jin; Lee, So Yeon; Park, Noh Hyuck; Ahn, Jin Hwan; Chung, Eun Chul; Kim, Sung Jun; Cha, Jang Gyu
- Abstract
Background There has been no comparison study to assess the diagnostic efficacy of additional anterior cruciate ligament (ACL) views in three-dimensional (3D) volume isotropic turbo spin-echo acquisition (VISTA) and two-dimensional (2D) fast spin-echo (FSE) T2-weighted (T2W) images for the diagnosis of ACL tear. Purpose To compare the diagnostic performances of additional ACL views on VISTA with those on the 2D FSE T2W images. Material and Methods This retrospective study included 78 patients who were suspected to have ACL injury and underwent both 2D TSE T2W magnetic resonance imaging (MRI) and 3D VISTA MRI of the knee between November 2012 and March 2013. The diagnostic performance of each oblique sagittal and coronal view and the combined images was evaluated for sensitivity, specificity, and accuracy for diagnosing an ACL tear. The arthroscopically and clinically confirmed diagnoses were used as the reference standard. The values were statistically analyzed using the McNemar test. Results The inter-observer agreement between two readers of the additional ACL views on 3D VISTA and 2D FSE T2W images were substantial on 2D FSE images and nearly concurred on the VISTA image. When considering both views of the oblique sagittal and coronal images, the inter-observer agreement between readers nearly concurred. There were no statistically significant differences in the sensitivity, specificity, and accuracy between 2D FSE images and VISTA images. Conclusion The performance of the additional ACL view on 3D VISTA MRI is comparable to that of 2D FSE T2W MRI in the diagnosis of ACL tear though the image quality of the 3D VISTA MRI is not equal to that of 2D FSE MRI.
- Subjects
ANTERIOR cruciate ligament; ELECTRON spin echoes; MAGNETIC resonance imaging; IMAGE processing; IMAGE quality analysis; COMPARATIVE studies; DIAGNOSTIC imaging; FREE radicals; KNEE; RESEARCH methodology; MEDICAL cooperation; COMPUTERS in medicine; PATIENT positioning; RESEARCH; RESEARCH evaluation; THREE-dimensional imaging; EVALUATION research; RETROSPECTIVE studies
- Publication
Acta Radiologica, 2016, Vol 57, Issue 11, p1372
- ISSN
0284-1851
- Publication type
journal article
- DOI
10.1177/0284185114568048