Radiation protection performance for the dismantling of the WWR-M primary cooling circuit.
- Authors
Lobach, Yu. N.; Luferenko, E. D.; Shevel, V. N.
- Abstract
The WWR-M is a light-water-cooled and moderated heterogonous research reactor with a thermal output of 10 MW. The reactor has been in operation for >50 y and has had an excellent safety record. A non-hermeticity of the inlet line of the primary cooling circuit (PCC) was found, and the only reasonable technical solution was the complete replacement of the PCC inlet and outlet pipe lines. Such a replacement was a challenging technical task due to the necessity to handle large size components with complex geometries under conditions of high-level radiation fields, and therefore, it required detailed planning aiming to reduce staff exposure. This paper describes the dismantling and removal of the PCC components focusing on radiation protection issues.
- Subjects
RADIATION protection; RADIOACTIVITY safety measures; NUCLEAR reactions; ALPHA rays; ATMOSPHERIC radiation