We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Performance Evaluation of TMD under Typhoon Using System Identification and Inverse Wind Load Estimation.
- Authors
Kang, Namcheol; Kim, Hongjin; Choi & Seongwoo Jo, Sunyoung; Hwang, Jae-Seung; Yu, Eunjong
- Abstract
The typhoon behavior and performance of a tuned mass damper (TMD) are presented based on the system identification and the inverse modal wind load estimation. The TMD was installed on a 39-story, 184.6-m steel building located in Incheon, Korea with a monitoring system consisting of an anemometer, accelerometers, and internet-based data logging system. On September 2, 2010, the building experienced the Kompasu Typhoon, in which the peak wind speed, measured by an anemometer installed on the roof floor, was 49.7 m/s. To analyze the behavior of the building during the typhoon, the dynamic properties of building and TMD are identified from the measured responses. The modal wind load is then inversely estimated from the TMD and building accelerations using a Kalman filter, and the vibration reduction performance of the TMD is evaluated. The analysis results show that the typhoon-induced vibration was reduced significantly due to the installation of TMD.
- Subjects
INCHON (Korea); KOREA; PERFORMANCE evaluation; SYSTEM identification; TUNED mass dampers; WIND pressure; STEEL buildings; KALMAN filtering
- Publication
Computer-Aided Civil & Infrastructure Engineering, 2012, Vol 27, Issue 6, p455
- ISSN
1093-9687
- Publication type
Article
- DOI
10.1111/j.1467-8667.2011.00755.x