An Ex Vivo Model for Reperfusion of Laryngotracheal Grafts.
- Authors
Barker, Emma; Macchiarini, Paolo; Murison, Pamela; Jones, Alan; Haverson, Karin; Bailey, Mick; Birchall, Martin
- Abstract
Objective: To describe the development of an ex vivo model to facilitate the study of ischemia-reperfusion injury in laryngotracheal grafts taken from Minnesota minipigs. Study Design: This is a descriptive study. Methods: Laryngotracheal grafts from Minnesota minipigs were harvested and placed in cold storage for 3 hours. Autologous blood was used to reperfuse the graft for up to 8 hours using the described reperfusion model. Results: By altering retrieval technique and pressures within the graft, we demonstrated healthy grafts after 8 hours of reperfusion. Conclusions: Ex vivo reperfusion offers a range of experimental advantages over in vivo reperfusion including close control of interventions, ease of outcome measurement, and reduction in animal use. This model is now ready to be used for further studies of interventions to reduce ischemia-reperfusion injury in these grafts.
- Publication
Laryngoscope, 2005, Vol 115, Issue 4, p699
- ISSN
0023-852X
- Publication type
Article
- DOI
10.1097/01.mlg.0000161330.75600.4b