We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Capillary electrophoresis–electrospray mass spectrometry and HR–ICP–MS for the detection and quantification of <sup>10</sup>B-boronophenylalanine (<sup>10</sup>B–BPA) used in boron neutron capture therapy.
- Authors
Pitois, Aurélien; Aldave de las Heras, Laura; Zampolli, Antonella; Menichetti, Luca; Carlos, Ramon; Lazzerini, Guido; Cionini, Luca; Salvatori, Pietro Alberto; Betti, Maria
- Abstract
Boron neutron capture therapy (BNCT) is a bimodal radiotherapeutic treatment based on the irradiation of neoplastic tissues with neutrons after the tissues have selectively accumulated molecules loaded with nuclides with large neutron capture cross-sections (such boron-10). Boron-10 carriers have been tested to a limited extent, and clinical trials have been conducted on sulfhydryl borane (10B-BSH) and boronophenylalanine (10B-BPA). However, precise and accurate measurements of boron-10 concentrations (0.1–100 μg/g) in specimens and samples of limited size (μg scale) are needed in order to be able to biologically characterise new compounds in predictive tissue dosimetry, toxicology and pharmacology studies as well as in clinical investigations. A new approach based on fast separation and detection of 10B-BPA performed by coupling capillary electrophoresis to electrospray mass spectrometry is reported. This method allows the quantitative analysis and characterisation of 10B-BPA in a short time with a high separation efficiency. Detection limits of 3 μM for 10B-BPA and 30 ng/mL for 10B were obtained with CE–ESI–MS. A quantification limit of 10 μM for 10B-BPA (100 ng/mL for 10B) was attained. The total boron-10 concentration was determined by high-resolution inductively coupled mass spectrometry in order to validate the method. Boron-10 isotope measurements were carried out by HR–ICP–MS at medium resolution (R=4000) due to the presence of an isobaric interference at mass 10. Good agreement was obtained between the values from CE–ESI–MS and those from HR–ICP–MS. The method has been successfully used to determine the 10B-BPA in two lines of cultured cells.
- Subjects
ELECTROPHORESIS; MASS spectrometry; ELECTROSPRAY ionization mass spectrometry; BORON-neutron capture therapy; CANCER radiotherapy; THERAPEUTIC use of boron isotopes
- Publication
Analytical & Bioanalytical Chemistry, 2006, Vol 384, Issue 3, p751
- ISSN
1618-2642
- Publication type
Article
- DOI
10.1007/s00216-005-0208-1