Cis-AB showing discrepant results across different automated and manual methods: a case report and review of the literature.
- Authors
Shin, Eunju; Kim, Hanah; Hur, Mina; Lee, Hyunkyung; Sohn, In-Sook; Park, Kyoung Un; Seo, Dong Hee
- Abstract
Before this admission, ABO grouping was performed three times in our hospital immunohematology laboratory, and her blood group was constantly determined to be A SP + sp , using ORTHO VISION Max analyzer (Ortho-Clinical Diagnostics, Raritan, NJ, USA). Keywords: ABO blood group; automated method; cis-AB; discrepancy; manual method EN ABO blood group automated method cis-AB discrepancy manual method e156 e159 4 07/04/23 20230701 NES 230701 To the Editor, ABO grouping is the most important pretransfusion testing that is directly related to the quality performance of immunohematology laboratories and patient safety [[1]]. On admission, however, it was notified that her blood group was determined to be I cis i -AB in a testing conducted in the other laboratory.