We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Root Cause Analysis Reports for MIC/MID Cases: Practical Tips.
- Authors
Javaherdashti, Reza
- Abstract
Electrochemical corrosion has four elements (anode, cathode, a metallic path, and electrolyte). For non-metals, the first three elements are absent. Thus, corrosion is exclusive used for metals and deterioration for non-metals. Microbiologically influenced corrosion (MIC) applies to metals and microbiologically influenced deterioration (MID) applies to non-metals such as polymers and composites. In this article, a four-step algorithm/guide to prepare root cause analysis reports for MIC/MID cases is presented. By applying this algorithm, making syntax errors in such analyses will become as low as possible.
- Subjects
ROOT cause analysis; MICROBIOLOGICALLY influenced corrosion; DETERIORATION of metals; NONMETALS
- Publication
Journal of Failure Analysis & Prevention, 2023, Vol 23, Issue 6, p2298
- ISSN
1547-7029
- Publication type
Article
- DOI
10.1007/s11668-023-01806-5