Robotic retrieval of Cu‐IUD from rectovaginal septum – a video vignette.
- Authors
Curtis, Thomas; Dowsett, Dolly; Simpson, Paul; Hernon, James; El Hadi, Ahmed; Shaikh, Irshad
- Abstract
Slides 23-25: With the IUD not yet freed, dissection continued from the contralateral sidewall of the rectovaginal septum, allowing greater space to release the IUD. Arm 1 held the main camera, arm 2 hot shears, which were swapped early in the procedure for a cautery hook, arm 3 a Cadiere forcep and arm 4 a fenestrated bipolar forcep. This video correspondence describes a case deploying the Da Vinci X robotic surgical system to retrieve a misplaced intrauterine contraceptive device (IUD), which had migrated to the rectovaginal septum.