We found a match
Your institution may have access to this item. Find your institution then sign in to continue.
- Title
Single-Strand "Short Isometric Construct" Medial Collateral Ligament Reconstruction Restores Valgus and Rotational Stability While Isolated Deep MCL and Superficial MCL Reconstruction Do Not.
- Authors
Borque, Kyle A.; Han, Shuyang; Dunbar, Nicholas J.; Lanfermeijer, Nicholas D.; Sij, Ethan W.; Gold, Jonathan E.; Ismaily, Sabir K.; Amis, Andrew A.; Laughlin, Mitzi S.; Kraeutler, Matthew J.; Williams, Andy; Lowe, Walter R.; Noble, Philip
- Abstract
Background: Historical MCL (medial collateral ligament) reconstruction (MCLR) techniques have focused on the superficial MCL (sMCL) to restore valgus stability while frequently ignoring the importance of the deep MCL (dMCL) in controlling tibial external rotation. The recent recognition of the medial ligament complex importance has multiple studies revisiting medial anatomy and questioning contemporary MCLR techniques. Purpose: To assess whether (1) an isolated sMCL reconstruction (sMCLR), (2) an isolated dMCL reconstruction (dMCLR), or (3) a novel single-strand short isometric construct (SIC) would restore translational and rotational stability to a knee with a dMCL and sMCL injury. Study Design: Controlled laboratory study. Methods: Biomechanical testing was performed on 14 fresh-frozen cadaveric knee specimens using a custom multiaxial knee activity simulator. The specimens were divided into 2 groups. The first group was tested in 4 states: intact, after sectioning the sMCL and dMCL, isolated sMCLR, and isolated dMCLR. The second group was tested in 3 states: intact, after sectioning the sMCL and dMCL, and after single-strand SIC reconstruction (SICR). In each state, 4 loading conditions were applied at 0°, 20°, 40°, 60°, and 90° of knee flexion: 8-N·m valgus torque, 5-N·m external rotation torque, 90-N anterior drawer, and combined 90-N anterior drawer plus 5-N·m tibial external rotation torque. Anterior translation, valgus rotation, and external rotation of the knee were measured for each state and loading condition using an optical motion capture system. Results: sMCL and dMCL transection resulted in increased laxity for all loading conditions at all flexion angles. Isolated dMCLR restored external rotation stability to intact levels throughout all degrees of flexion, yet valgus stability was restored only at 0° of flexion. Isolated sMCLR restored valgus and external rotation stability at 0°, 20°, and 40° of flexion but not at 60° or 90° of flexion. Single-strand SICR restored valgus and external rotation stability at all flexion angles. In the combined anterior drawer plus external rotation test, isolated dMCL and single-strand SICR restored stability to the intact level at all flexion angles, while the isolated sMCL restored stability at 20° and 40° of flexion but not at 60° or 90° of flexion. Conclusion: In the cadaveric model, single-strand SICR restored valgus and rotational stability throughout the range of motion. dMCLR restored rotational stability to the knee throughout the range of motion but did not restore valgus stability. Isolated sMCLR restored external rotation and valgus stability in early flexion. Clinical Relevance: In patients with anteromedial rotatory instability in the knee, neither an sMCLR nor a dMCLR is sufficient to restore stability.
- Subjects
MEDIAL collateral ligament (Knee); BIOMECHANICS; STATISTICAL power analysis; DATA analysis; MEDICAL cadavers; FISHER exact test; TREATMENT effectiveness; TORQUE; ANTERIOR cruciate ligament; DESCRIPTIVE statistics; ROTATIONAL motion; STATISTICS; PLASTIC surgery; DATA analysis software; JOINT instability; RANGE of motion of joints
- Publication
American Journal of Sports Medicine, 2024, Vol 52, Issue 4, p968
- ISSN
0363-5465
- Publication type
Article
- DOI
10.1177/03635465231224477